A-12
Cisco ASR 9000 Series Aggregation Services Router Overview and Reference Guide
OL-17501-09
Appendix A Technical Specifications
Table A-17 lists the AC input voltage range for the AC-powered Cisco ASR 9000 Series Routers
(single-phase power source).
Table A-18 lists the DC input voltage range for the DC-powered Cisco ASR 9000 Series Routers.
Table A-19 lists the DC output tolerances for AC or DC power modules for the version 1 power system.
Table A-17 AC Input Voltage Range
Range Minimum
Minimum
Nominal Nominal
Maximum
Nominal Maximum
Input Voltage 180 VAC 200 VAC 220 VAC 240 VAC 264 VAC
Line Frequency 47 Hz 50 Hz 50/60 Hz 60 Hz 63 Hz
Table A-18 DC Input Voltage Range
Range Minimum Nominal Maximum
Input Voltage –40 VDC –48 VDC –72 VDC
Table A-19 DC Output Levels for Version 1 Power System
Parameter Value
Voltage
Maximum –54.5 VDC
Nominal –54.0 VDC
Minimum –53.5 VDC
Power
Minimum (one power module) 1500 W
Maximum (three 2100 W power modules per tray x two
trays)
12,600 W (Cisco ASR 9010 Router only)
1
1. Maximum output power the power system is capable of supporting (not system power consumption).
Maximum (three 2100 W power modules in a single tray) 6300 W (Cisco ASR 9006 Router only)

Table of Contents

Other manuals for Cisco ASR 9006

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Cisco ASR 9006 and is the answer not in the manual?

Cisco ASR 9006 Specifications

General IconGeneral
BrandCisco
ModelASR 9006
CategoryNetwork Router
LanguageEnglish

Related product manuals