EasyManua.ls Logo

Cisco ASR1000-RP1 - ASR 1000 Series Route Processor 1 Router - Configuring a Synce Using the Line-To-External Method

Cisco ASR1000-RP1 - ASR 1000 Series Route Processor 1 Router
378 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
10-9
Cisco ASR 1000 Series Aggregation Services Routers Software Configuration Guide
OL-16506-10
Chapter 10 Synchronous Ethernet Support
Configuring Synchronous Ethernet
Examples
The following example shows how to configure clock recovery from a BITS port for Metronome SPA on
ASR 1000 Series Routers:
Router>enable
Router# configure terminal
Router(config)# network-clock synchronization automatic
Router(config)# network-clock synchronization ssm option 2 GEN1
Router(config)# network-clock input-source 1 External 0/0/0 t1 esf
Router(config)# exit
The following example shows how to configure clock recovery from a BITS port for RP BITS on ASR
1000 Series Routers with dual RP R0/R1:
Router>enable
Router# configure terminal
Router(config)# network-clock synchronization automatic
Router(config)# network-clock synchronization ssm option 2 GEN1
Router(config)# network-clock input-source 1 External R0 t1 esf
Router(config)# exit
Configuring a SyncE Using the Line-to-External Method
This section describes how to configure a SyncE using the Line-to-External method.
SUMMARY STEPS
1. enable
2. configure terminal
3. network-clock synchronization automatic
4. network-clock synchronization ssm option option_Id Generation_Id
5. interface gigabitethernet slot/port
6. synchronous mode
7. exit
8. network-clock output-source line priority {interface interface_name} {external slot/card/port}
9. exit
DETAILED STEPS
Command Purpose
Step 1
enable
Example:
Router# enable
Enables the privileged EXEC mode.
Enter your password if prompted.
Step 2
configure terminal
Example:
Router# configure terminal
Enters the global configuration mode.

Table of Contents