Back Panel
Please note that the serial number is located on the product label at the back panel of the MX85.
Reset button
Insert a paper clip if a reset is required.
• A brief, momentary press: To delete a downloaded configuration and reboot.
• Press and hold for more than 10 seconds: To force the unit into a full factory reset.
Mounting Recommendations
When installing the appliance, make sure that there is sufficient space between the rear of the rack and other obstacles to ensure adequate airflow. Ventilation is
from side to side not from front to back. This MX security appliance requires a minimum of 10mm clearance between the venting holes and any obstruction.
Safety and Warnings
Warning: The system must be disconnected from all sources of power and the power cord removed from the power supply module(s)
before accessing, installing, or removing system components.
Caution: The Optical Transceiver product should use UL listed, and Rated Laser Class I, 3.3Vdc.
These operations are to be taken with respect to all local laws. Please take the following into consideration for safe operation:
• Power off the unit before you begin. Read the installation instructions before connecting the system to the power
source.
• Before you work on any equipment, be aware of the hazards involved with electrical circuitry and be familiar with
standard practices for preventing accidents.
• Read the mounting instructions carefully before beginning installation. Failure to use the correct hardware or to
follow the correct procedures could result in a hazardous situation to people and damage to the system.
• This product relies on the building’s installation for short-circuit (overcurrent) protection. Ensure that the protective
device is rated not greater than: 15 A, 125 Vac, or 10A, 240 Vac.
• Please only power the device with the provided power cables to ensure regulatory compliance.
Pre-install Preparation
You should complete the following steps before going on-site to perform an installation.
5