Cisco UCS C22 M3 High-Density SFF Rack-Mount Server
CONFIGURING the SERVER
17
Approved Configurations
Select a software RAID option from Table 5 on page 15 or a single plug-in PCIe RAID controller
from Table 6. You may also select an appropriate optional RAID configuration option listed in
Tab le 6 for plug-in PCIe RAID cards.
Caveats
■ In 1-CPU configurations, there is only one full-height PCIe slot available (located on riser 1).
— If you choose software RAID, you can select one additional optional PCIe card from
Tab le 8 on page 21
—If you choose a plug-in RAID controller from Table 5 on page 15, you will not be
able to select any optional PCIe card from Table 8 on page 21.
RAID Configuration Options (not available for LSI MegaSR software RAID)
R2XX-RAID0 Factory preconfigured RAID striping option
Enable RAID 0 Setting. Requires a minimum of one hard drive.
R2XX-RAID1 Factory preconfigured RAID mirroring option
Enable RAID 1 Setting. Requires exactly two drives with the same size, speed,
capacity.
R2XX-RAID5 Factory preconfigured RAID option
Enable RAID 5 Setting. Requires a minimum of three drives of the same size,
speed, capacity.
R2XX-RAID6 Factory preconfigured RAID option
Enable RAID 6 Setting. Requires a minimum of four drives of the same size,
speed, capacity.
R2XX-RAID10 Factory preconfigured RAID option
Enable RAID 10 Setting. Requires an even number of drives (minimum of four
drives) of the same size, speed, capacity.
NOTE: Although RAID levels 50 and 60 are not orderable from the factory, they are
supported for selected controllers as shown in
Table 5.
NOTE: No RAID factory preconfigured RAID option can be chosen (a factory RAID
volume cannot be configured) if:
■ there are no drives, or
■ SAS and SATA drives are mixed, or
■ different capacity drives are mixed
Table 6 Available Hardware RAID Options (continued)
Product ID (PID) PID Description