Table 6. RAID 10
RAID 10
Uses
Appropriate when used with data storage that needs 100 percent redundancy of mirrored drive groups and that
also needs the enhanced I/O performance of RAID 0 (striped drive groups)
Works well for medium-sized databases
Advantages
Provides both high data transfer rates and complete data redundancy
Limitations
Requires twice as many drives as all other RAID levels
Drives
4 through 32 in multiples of 4 (limited by the maximum number of drives supported by the controller using an even
number of drives in each RAID 10 virtual drive in the span)
Figure 7. RAID 10 Drive Group
RAID 50
RAID 50 is a combination of RAID 5 and RAID 0 (5 + 0). RAID 50 includes both parity and disk striping across
multiple drive groups. It is best implemented on two RAID 5 drive groups with data striped across both drive
groups.
RAID 50 divides data into smaller blocks and then stripes the blocks of data to each RAID 5 disk set. RAID 5
divides data into smaller blocks, calculates parity by performing an exclusive-or operation on the blocks, and then
writes the blocks of data and parity to each drive in the drive group. The size of each block is determined by the
stripe size parameter, which is set during the creation of the RAID set.
RAID 50 can support up to eight spans and tolerate up to eight drive failures, though less than the drive capacity is
available. Although multiple drive failures are tolerated, only one drive failure is tolerated in each RAID 5 drive
group.
RAID 50 is excellent for environments that require high reliability, high request rates, high data transfer, and
medium-sized to large capacity. Table 7 provides an overview of RAID 50. Figure 8 shows an example of RAID 50
use.

Other manuals for Cisco UCS C220 M3

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Cisco UCS C220 M3 and is the answer not in the manual?

Cisco UCS C220 M3 Specifications

General IconGeneral
Tcase70 °C
Bus typeQPI
SteppingM1
FSB ParityNo
Scalability2S
Processor cache10 MB
Processor cores4
System bus rate6.4 GT/s
Processor seriesIntel Xeon E5-2600
Processor socketLGA 2011 (Socket R)
Processor codenameSandy Bridge EP
Processor frequency2.4 GHz
Processor cache typeSmart Cache
Processor manufacturerIntel
Processor package size52.5 x 45.0 mm
Processor front side bus- MHz
Processor boost frequency2.50 GHz
Processor operating modes64-bit
ECC supported by processorYes
Graphics & IMC lithography32 nm
PCI Express configurationsx4, x8, x16
Supported instruction setsAVX
Thermal Design Power (TDP)80 W
Number of processors installed2
CPU multiplier (bus/core ratio)24
Physical Address Extension (PAE)46 bit
Maximum number of PCI Express lanes40
Memory types supported by processorDDR3-SDRAM
Memory channels supported by processorQuad
Memory clock speeds supported by processor800, 1066 MHz
Memory bandwidth supported by processor (max)34.1 GB/s
Maximum internal memory supported by processor750 GB
HDD size2.5 \
HDD interface-
Total storage capacity500 GB
Compatible memory cardsSD
Maximum storage capacity- TB
Memory slots16
Internal memory32 GB
Memory clock speed1866 MHz
Maximum internal memory- GB
USB 2.0 ports quantityUSB 2.0 ports have a data transmission speed of 480 Mbps, and are backwards compatible with USB 1.1 ports. You can connect all kinds of peripheral devices to them.
Ethernet LAN (RJ-45) ports3
Chassis typeRack (1U)
Power supply450 W
SafetyUL 60950-1 No. 21CFR1040, CAN/CSA-C22.2 No. 60950-1, IEC 60950-1, EN 60950-1, IEC 60950-1, AS/NZS 60950-1, GB4943 2001
Certification47CFR Part 15 (CFR 47), AS/NZS CISPR22, CISPR2 2, EN55022, ICES003, VCCI, EN61000-3-2, EN61000-3-3, KN22, CNS13438, EN55024, CISPR24, EN300386, KN24
Operating altitude0 - 3000 m
Non-operating altitude0 - 12000 m
Storage temperature (T-T)-40 - 70 °C
Operating temperature (T-T)0 - 40 °C
Storage relative humidity (H-H)5 - 93 %
Operating relative humidity (H-H)10 - 90 %
PCI Express slots version3.0
Processor ARK ID64588
Intel Secure Key Technology version1.00
Intel Identity Protection Technology version0.00
Harmonized System (HS) code84714100
Weight and Dimensions IconWeight and Dimensions
Depth724 mm
Width430 mm
Height43.2 mm