9
3. Take the three (3) bolt sets and install the black bracket to the open side of the
pre-clean shelf
4. Attach the bottom of the bracket to the main body of the unit.
5. Insert grey plastic bin into brackets underneath shelf.
6. Lay black plastic insert/shelf liner onto pre-clean shelf (prevents scratches)
Congratulations your unit is ready!
VI. PARTS DESCRIPTION & OPERATION
A. Solvent Flow Switch
1. To start the solvent flow from the brush and wand nozzle, simply turn the
switch to “ON”. To stop the flow of the solvent, turn the switch to “OFF”.
(NOTE: Models built prior to June 2012 were equipped with a 4-minute timer
and a green push button. The green push button turns the system on for a 4-minute cycle.
When the cycle is over the system will shut off automatically. If continued operation is
needed, simply depress the green “ON” button again.
B. Light Switch
(Standard on PCS/WCS; Optional on RPW/RWC models). The light switch on the
control panel operates the overhead 150-watt halogen light. The light does not
automatically switch off, so the operator must manually turn the light off.
C. Cleaning Brush
This ergonomically designed Parts Cleaning brush self cleans during use.
D. Optional Add-on Features
The Cleaner can be customized with additional features to make your shop’s parts and/or
weapons cleaning even more efficient. The following describes the operation of these
options; however, not all units are equipped with the same option packages.
Air Tool with Air Pump
If the optional Air Tool with Air Pump was purchased for your Cleaner, you will have an
air nozzle/handle hanging on the inside of the Cleaner lid. The air flow is controlled by
the Solvent Flow switch.
To activate the air tool, first turn the Solvent Flow Switch to “ON”, starting the
compressor. Next, take hold of the Air Tool, point it down and away from your body
and depress the trigger on the handle to release the pressurized air.
Regulated Shop Air Operated Air Tool
If the optional regulated “Shop Air” model was purchased, hook up the Shop Air Hose
to the air regulator located on the backside of the lower shelf. Manually adjust the
amount of air needed by pulling up the knob on the regulator and turning it to the