EasyManuals Logo
Home>Daikin>Air Conditioner>2MXM50M2V1B

Daikin 2MXM50M2V1B User Manual

Daikin 2MXM50M2V1B
26 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #10 background imageLoading...
Page #10 background image
5 English
Installation
Install the unit horizontally.
The unit may be installed directly on a concrete verandah or a solid place if drainage is good.
If the vibration may possibly be transmitted to the building, use a vibration-proof rubber (field supply).
1. Connections (connection port)
Install the indoor unit according to the table below, which shows the relationship between the class of indoor unit and the
corresponding port.
The total indoor unit class that can be connected to this unit:
How to Use Reducers
Use the reducers supplied with the unit as described below.
Connecting a pipe of φ9.5 to a gas pipe connection port for φ12.7:
Precautions on Installation
Check the strength and level of the installation ground so that the unit will not cause any operating vibration or noise after installed.
In accordance with the foundation drawing in fix the unit securely by means of the foundation bolts. (Prepare 4 sets of M8 or M10
foundation bolts, nuts and washers each which are available on the market.)
It is best to screw in the foundation bolts until their ends are 20mm from the foundation surface.
When using the reducer packing shown above, be careful not to overtighten
the nut, or the smaller pipe may be damaged. (about 2/3 - 1 the normal torque)
Apply a coat of refrigeration oil to the threaded connection port of the outdoor
unit where the flare nut comes in.
Use an appropriate wrench to avoid damaging the connection thread by over-
tightening the flare nut.
Flare nut tightening torque
Flare nut for
φ12.7
49.5–60.3N·m
(505–615kg-
f·cm)
2AMXM40M*
2MXM40M*
2AMXM50M*
2MXM50M*
A
B
20 ,15, 25,35,42,50
20 ,15 , 25 , 35 , 42
20 , 25 , 35
20 ,
15 ,
15 , 25 , 35
2AMXM40M*
2MXM40M*
2AMXM50M*
2MXM50M*
: Use a reducer to connect pipes.
Refer to “How to Use Reducers” for information on reducer numbers and their shapes.
Port
Up to 6.0kW Up to 8.5kW
Heat pump type:
No. 2
No. 1
Connection port of outdoor unit
Flare nut (for φ12.7)
Inter-unit piping
Be sure to attach the gasket.
20

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Daikin 2MXM50M2V1B and is the answer not in the manual?

Daikin 2MXM50M2V1B Specifications

General IconGeneral
BrandDaikin
Model2MXM50M2V1B
CategoryAir Conditioner
LanguageEnglish

Related product manuals