2 Specific installer safety instructions
Installation manual
5
4MWXM-A9
R32 Split series
3P600450-7T – 2022.09
The full set of latest technical data is available on the Daikin
Business Portal (authentication required).
2 Specific installer safety
instructions
Always observe the following safety instructions and regulations.
Unit installation (see "4Unit installation"[46])
WARNING
Installation shall be done by an installer, the choice of
materials and installation shall comply with the applicable
legislation. In Europe, EN378 is the applicable standard.
Installation site (see "4.1Preparing the installation site"[47])
CAUTION
Check if the installation location can support the unit's
weight. Poor installation is hazardous. It can also cause
vibrations or unusual operating noise.
Provide sufficient service space.
Do NOT install the unit so that it is in contact with a
ceiling or a wall, as this may cause vibrations.
WARNING
The appliance shall be stored so as to prevent mechanical
damage and in a well-ventilated room without continuously
operating ignition sources (e.g. open flames, an operating
gas appliance, or an operating electric heater). The room
size shall be as specified in the General safety precaution.
Piping installation (see "5Piping installation"[48])
CAUTION
Piping and joints of a split system shall be made with
permanent joints when inside an occupied space except
joints directly connecting the piping to the indoor units.
CAUTION
No brazing or welding on site for units with R32
refrigerant charge during shipment.
During installation of the refrigeration system, joining of
parts with at least one part charged shall be performed
taking into account the following requirements: inside
occupied spaces non-permanent joints are NOT
allowed for R32 refrigerant except for site made joints
directly connecting the indoor unit to piping. Site made
joints directly connecting piping to indoor units shall be
of non-permanent type.
CAUTION
Do NOT connect the embedded branch piping and the
outdoor unit when only carrying out piping work without
connecting the indoor unit in order to add another indoor
unit later.
WARNING
Connect the refrigerant piping securely before running the
compressor. If the refrigerant piping is NOT connected and
the stop valve is open when the compressor is run, air will
be sucked in. This will cause abnormal pressure in the
refrigeration cycle, which may result in equipment damage
and even injury.
CAUTION
Incomplete flaring may cause refrigerant gas leakage.
Do NOT re-use flares. Use new flares to prevent
refrigerant gas leakage.
Use flare nuts that are included with the unit. Using
different flare nuts may cause refrigerant gas leakage.
CAUTION
Do NOT open the valves before flaring is complete. This
would cause refrigerant gas leakage.
DANGER: RISK OF EXPLOSION
Do NOT open the stop valves before the vacuum drying is
finished.
Charging refrigerant (see "6Charging refrigerant"[410])
WARNING: MILDLY FLAMMABLE MATERIAL
The refrigerant inside this unit is mildly flammable.
WARNING
The refrigerant inside the unit is mildly flammable, but
normally does NOT leak. If the refrigerant leaks in the
room and comes in contact with fire from a burner, a
heater, or a cooker, this may result in fire, or the
formation of a harmful gas.
Turn OFF any combustible heating devices, ventilate
the room, and contact the dealer where you purchased
the unit.
Do NOT use the unit until a service person confirms
that the part from which the refrigerant leaked has been
repaired.
WARNING
Only use R32 as refrigerant. Other substances may
cause explosions and accidents.
R32 contains fluorinated greenhouse gases. Its global
warming potential (GWP) value is 675. Do NOT vent
these gases into the atmosphere.
When charging refrigerant, ALWAYS use protective
gloves and safety glasses.
WARNING
NEVER directly touch any accidental leaking refrigerant.
This could result in severe wounds caused by frostbite.
Electrical installation (see "7Electrical installation"[411])
WARNING
All wiring MUST be performed by an authorised
electrician and MUST comply with the applicable
national wiring regulation.
Make electrical connections to the fixed wiring.
All components procured on-site and all electrical
construction MUST comply with the applicable
legislation.
WARNING
ALWAYS use multicore cable for power supply cables.
WARNING
Use an all-pole disconnection type breaker with at least
3 mm between the contact point gaps that provides full
disconnection under overvoltage category III.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Daikin 4MWXM52A2V1B9 and is the answer not in the manual?

Daikin 4MWXM52A2V1B9 Specifications

General IconGeneral
BrandDaikin
Model4MWXM52A2V1B9
CategoryAir Conditioner
LanguageEnglish

Related product manuals