4 Operation
User reference guide
17
EGSAH/X06+10(U)DA9W(G)
Daikin Altherma 3 GEO
4P569819-1A – 2019.10
4.6.4 To change the desired room temperature
During room temperature control, you can use the room temperature
setpoint screen to read out and adjust the desired room temperature.
1 Go to [1]: Room.
Room
1
2 Adjust the desired room temperature.
+
21°C
1
a b
Room
a Actual room temperature
b Desired room temperature
If scheduling is on after changing the desired room temperature
The temperature will stay the same as long as there is no
scheduled action.
The desired room temperature will return to its scheduled value
whenever a scheduled action occurs.
You can avoid scheduled behaviour by (temporarily) turning off
scheduling.
To turn off room temperature scheduling
1 Go to [1.1]: Room > Schedule.
2 Select No.
4.6.5 To change the desired leaving water
temperature
INFORMATION
The leaving water is the water that is sent to the heat
emitters. The desired leaving water temperature is set by
your installer in accordance with the heat emitter type.
Only adjust the leaving water temperature settings in case
of problems.
You can use the leaving water temperature setpoint screen to read
out and adjust the desired leaving water temperature.
1 Go to [2]: Main zone or [3]: Additional zone.
Main zone
2
Additional zone
3
2 Adjust the desired leaving water temperature.
+
35°C
2
a b
Main zone
+
45°C
3
a b
Additional zone
a Actual leaving water temperature
b Desired leaving water temperature
If scheduling is on after changing the desired leaving water
temperature
The temperature will stay the same as long as there is no
scheduled action.
The desired leaving water temperature will return to its scheduled
value whenever a scheduled action occurs.
You can avoid scheduled behaviour by (temporarily) turning off
scheduling.
To turn off leaving water temperature scheduling
1 Go to one of the following:
[2.1]: Main zone > Schedule
[3.1]: Additional zone > Schedule
2 Select No.
To enable weather-dependent operation for the leaving water
temperature
See "4.9.4Using weather-dependent curves"[425].

Table of Contents

Other manuals for Daikin Altherma 3 GEO

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Daikin Altherma 3 GEO and is the answer not in the manual?

Daikin Altherma 3 GEO Specifications

General IconGeneral
BrandDaikin
ModelAltherma 3 GEO
CategoryHeat Pump
LanguageEnglish

Related product manuals