5 | Operation
User reference guide
44
EBBH/X11+16DF + EBVH/X11+16S(U)18+23DJ
Daikin Altherma 3 R F+W
4P643607-1 – 2021.09
For the procedure to set the electricity price, see "To set the electricity
price"[443].
Example
This is an example and the prices and/or values used in this example are NOT
accurate.
Data Price/kWh
Gas price 4.08
Electricity price 12.49
Renewable heat incentive per kWh 5
Calculation of the gas price
Gas price=Actual gas price+(Incentive/kWh×0.9)
Gas price=4.08+(5×0.9)
Gas price=8.58
Calculation of the electricity price
Electricity price=Actual electricity price+Incentive/kWh
Electricity price=12.49+5
Electricity price=17.49
Price Value in breadcrumb
Gas: 4.08/kWh [7.6]=8.6
Electricity: 12.49/kWh [7.5.1]=17
5.9 Weather-dependent curve
5.9.1 What is a weather-dependent curve?
Weather-dependent operation
The unit operates 'weather dependent' if the desired leaving water or tank
temperature is determined automatically by the outdoor temperature. It therefore
is connected to a temperature sensor on the North wall of the building. If the
outdoor temperature drops or rises, the unit compensates instantly. Thus, the unit
does not have to wait for feedback by the thermostat to increase or decrease the
temperature of the leaving water or tank. Because it reacts more quickly, it
prevents high rises and drops of the indoor temperature and water temperature at
tap points.
Advantage
Weather-dependent operation reduces energy consumption.
Weather-dependent curve
To be able to compensate for differences in temperature, the unit relies on its
weather-dependent curve. This curve defines how much the temperature of the
tank or leaving water must be at different outdoor temperatures. Because the
slope of the curve depends on local circumstances such as climate and the
insulation of the house, the curve can be adjusted by an installer or user.

Table of Contents

Other manuals for Daikin Altherma 3 R F+W

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Daikin Altherma 3 R F+W and is the answer not in the manual?

Daikin Altherma 3 R F+W Specifications

General IconGeneral
BrandDaikin
ModelAltherma 3 R F+W
CategoryHeat Pump
LanguageEnglish

Related product manuals