4 | Operation
User reference guide
26
EHBH/X04+08EA/EJ6V+9W + EHVH/X04+08S(U)18+23EA/EJ3V+6V+9W
Daikin Altherma 3 R F+W
4P629087-1 – 2020.08
t
T
t
60°C
00:00 07:00
50°C
45°C
15°C
14:00 21:00
35°C
1
2
4
5
3
T
t
Domestic hot water tank temperature
t Time
4.5.5 To change the domestic hot water temperature
In Reheat only mode, you can use the tank temperature setpoint screen to read
out and adjust the domestic hot water temperature.
1 Go to [5]: Tank.
Tank
5
2 Adjust the domestic hot water temperature.
+
50°C
5
a b
Tank
a Actual domestic hot water temperature
b Desired domestic hot water temperature
In other modes, you can only view the setpoint screen but not modify it. Instead,
you can modify the settings for the Comfort setpoint [5.2], Eco setpoint
[5.3] and Reheat setpoint [5.4].
4.5.6 Using DHW powerful operation
About powerful operation
Powerful operation allows the domestic hot water to be heated by the
backup heater or booster heater. Use this mode on days when there is more hot
water usage than usual.
To check if powerful operation is active
If is displayed on the home screen, powerful operation is active.
Activate or deactivate Powerful operation as follows:
1 Go to [5.1]: Tank > Powerful operation
2 Turn powerful operation Off or On.
Usage example: You immediately need more hot water
You are in the following situation:

Table of Contents

Other manuals for Daikin Altherma 3 R W

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Daikin Altherma 3 R W and is the answer not in the manual?

Daikin Altherma 3 R W Specifications

General IconGeneral
TypeAir-to-water heat pump
RefrigerantR-32
Energy Efficiency Class (Heating)A+++
Energy Efficiency Class (Cooling)A++
Operating Temperature Range (Heating)-25°C to 35°C
Operating Temperature Range (Cooling)10°C to 46°C
Heating Capacity4.0 - 16.0 kW
Sound Power Level62 dBA