4.
Description
of
the
operation
modes
1
FAN
ONLY
OPERATION
C2)
In
this
mode,
air
only
circulates
without
heating
or
cooling.
2
DRY
OPERATION
[44]
In
this
mode,
the
air
humidity
will
be
lowered
with
a
minimal
temperature
decrease.
The
temperature
and
fan
speed
are
controlled
automatically
and
cannot
be
controlled
by
the
remote
controller,
Dry
operation
will
not
function
if
the
room
temperature
is
too
low.
3
AUTOMATIC
OPERATION
{Al
In
this
mode,
the
controller
will
automatically
switch
between
heating
and
cooling
as
required
by
the
setpoint
or
limit
temperature.
4
COOLING
OPERATION
Ft
In
this
mode,
cooling
will
be
activated
as
required
by
the
setpoint
or
limit
temperature.
5
HEATING
OPERATION
In
this
mode,
heating
will
be
activated
as
required
by
the
setpoint
or
limit
temperature.
Hot
start
(heat
pump
types
only)
At
the
start
of
a
heating
operation,
the
indoor
fan
is
stopped
until
a
certain
indoor
heat
exchanger
temperature
is
reached
and
is
displayed.
This
prevents
cald
air
from
leaving
the
indoor
unit.
Defrost
(heat
pumip
types
only)
In
heating
operation,
freezing
of
the
outdoor
heat
exchanger
may
occur.
If
so,
the
heating
capacity
of
the
system
lowers
and
the
system
goes
into
defrost
operation.
The
indoor
unit
fan
stops
and
[6/(@®
ea]
is
displayed.
After
maximum
10
minutes
of
defrost
operation,
the
system
returns
to
heating
operation
again.
6
LIMIT
OPERATION
i"
g
max
Limit
operation
is
an
additional
made
that
enables
to
keep
the
room
temperature
within
certain
limits.
The
Rn
&
MX
icons
are
displayed
to
confirm
the
activation
of
the
limit
operation,
7
LEAVE
HOME
We
LEAVE
HOME
is
a
feature
that
enables
to
keep
the
toom
temperature
above
10°C
when
the
occupants
are
out.
This
function
will
switch
on
heating
if
the
installation
is
switched
off.
5.
Operation
Manual
operation
In
manual
operation,
the
user
decides
about
the
settings
of
the
installation.
The.
last
setting
remains
active
until
the
user
changes
it,
As
the
controller
can
be
implemented
for
a
wide
variety
of
installations
and
features,
it
might
occur
that
you
select
a
function
that
is
not
available
on
your
installation;
if
this
Is
the
case,
the
WARE
message
will
appear.
Operation
manual
5
DAIKIN
BRC1D61
Remote
controller
3P107422-3D

Other manuals for Daikin BRC1D61

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Daikin BRC1D61 and is the answer not in the manual?

Daikin BRC1D61 Specifications

General IconGeneral
DisplayLCD
Dimensions120 x 120 x 18 mm
Temperature Setting Range10°C to 32°C
CompatibilityDaikin SkyAir and VRV systems
Power Supply12V DC (supplied from indoor unit)

Related product manuals