EasyManuals Logo

Daikin DM80SN User Manual

Daikin DM80SN
44 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #39 background imageLoading...
Page #39 background image
1 STAGE STATUS CODES
39
Main
Menu
Option Menu
Active Alarm menu
xx
( xx: code numbers )
Last 6 Faults
F xx
( xx: code numbers )
Code Release Number
CR Number
Reset to Factory Default
F yes, no
Blower Speed for Continous Fan Mode
F Fxx
( xx: Blower Speed Number F01, F02.. )
Blower Speed for 1st Stage
Compressor Mode
Fxx
( xx: Blower Speed Number F01, F02.. )
Blower Speed for 2nd Stage
Compressor Mode
Fxx
( xx: Blower Speed Number F01, F02.. )
Cool On Delay

Delay, Seconds
Default set at 7 Secs, Adjustments can
be made in 7 Secs increments from 0 to
35 Secs
Cool Off Delay
Delay, Seconds
Default set at 65 Secs, Adjustments
can be made in 5 Secs increments from
0 to 120 Secs
Blower Speed for Gas Heat Mode
F Fxx
( xx: Blower Speed Number F01, F02.. )
Gas Heat On Delay

Delay, Seconds
Default set at 30 Secs, Adjustments
c
an be made in 5 Secs increments from
5 to 30 Secs
Gas heat Off Delay
F
Delay, Seconds
Default set at 90 Secs, Adjustments
can be made in 30 Secs increments from
30 to 180 Secs
Automatic Heat Staging - For Two
Stage Control
no, 10, 20, 30,
60, AUt
Refer to Section " CHANGING
HEATING MODE SETTING"
Menu Description
LED Display
Notes

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Daikin DM80SN and is the answer not in the manual?

Daikin DM80SN Specifications

General IconGeneral
BrandDaikin
ModelDM80SN
CategoryFurnace
LanguageEnglish

Related product manuals