Under some conditions, the fuel or air supply can create a
nearly invisible coating on the ame sensor. This coating
acts as an insulator causing a drop in the ame sense
signal. If the ame sense signal drops too low the furnace
will not sense ame and will lock out. The ame sensor
should be carefully cleaned by a qualied servicer using
emery cloth or steel wool. Following cleaning, the ame
sense signal should be as indicated in the Specications
Sheet.

The heat exchanger ue passageways should be
inspected at the beginning of each heating season.

Cycle the furnace with the thermostat at least three
times. Verify cooling and fan only operation.
Review the Owner’s Manual with the homeowner and
discuss proper furnace operation and maintenance.
Leave literature packet near furnace.

When ordering any of the listed functional parts, be
sure to provide the furnace model, manufacturing,
and serial numbers with the order.
Although only functional parts are shown in the parts
list, all sheet metal parts, doors, etc. may be ordered
by description.
Parts are available from your distributor.

Gas Valve Blower Motor
Gas Manifold Blower Wheel
Natural Gas Orice Blower Mounting Bracket
Propane Gas Orice Blower Cuto󰀨
Igniter Blower Housing
Flame Sensor Pressure Switch
Rollout Limit Switch Door Switch
Primary Limit Switch Auxiliary Limit Switch
Coil Front Cover Integrated Control Module
Transformer Door Switch
Induced Draft Blower
Heat Exchanger with Recuperator Coil