52 Photocatalytic Air Purifiers
Removal Procedure SiBE81-623A
7.5 Removal of Electrical Box / PCB
Warning Be sure to wait 10 minutes or more after turning off all power supplies before
disassembling work.
Procedure Points
* Remove the back
cover.
* Disconnect the fan
motor connector.
1. Disconnecting the
faston terminal
(1) Disconnect the
terminal located at
left.
(2) Disconnect the
terminal located at
right.
2. Removing the
electrical box
* The screws are M4×12
in size. (The other
ones are M4×16.)
Use regular length of
screws.
(1) Remove the 2 screws
from the front bottom.

Other manuals for Daikin MC707VM-S