46 Photocatalytic Air Purifiers
Removal Procedure SiBE81-623A
7.3 Removal of lonizing Wire
Warning Be sure to wait 10 minutes or more after turning off all power supplies before
disassembling work.
Procedure Points
Part A
1. Removing the
counter grid
(1) Undo the outer hook
and lift the counter
grid to detach.
(2) Zoomed up view of
part A.
Part A
* When assembling, fit the
position in the groove.
Hook
Hook
Counter grid
Groove