2 User Guide RS8GR602 © Danfoss 2016-10 AK-CT 450A
Introduction
Application
Complete refrigeration appliance control with great exibility to
adapt to all types of refrigeration appliances and cold storage
rooms.
• For refrigeration with brine
• For use with a thermostatic expansion valve (TEV)
Advantages
• Optimised for installation by manufacturer
• Electricity-controlled and voltage controlled relay connections
• Loads requiring electricity can be connected directly
• Overcurrent limitation
Energy optimisation of the whole refrigeration appliance
One controller for several dierent refrigeration appliances
Quick set-up with predened settings
Built-in data communication
Built-in clock function with power reserve
Principle
The temperature in the appliance is registered by one or two
temperature sensors which are located in the air ow before the
evaporator (S3) or after the evaporator (S4) respectively.
A setting for thermostat, alarm thermostat and display reading
determines the inuence the two sensor values should have for
each individual function.
In addition product sensor S6, which can be optionally placed in
the appliance, can be used to register the temperature near the
required product in a certain place within the appliance.
The temperature of the evaporator is registered with the S5 sensor
which can be used as a defrosting sensor.
In addition to the output for the solenoid valve type EVR the con-
troller has 9 relay outputs which are dened by the use selected –
the individual usage options are described in detail on page 12
Functions
Day/night thermostat with ON/OFF or modulating principle
Product sensor S6 with separate alarm limits
Switch between thermostat settings via digital input
Start of defrost via schedule, digital input or network
Natural, electric, hot gas defrost or brine defrost
Stop of defrost on time and/or temperature
Coordination of defrosting among several controls
Pulsing of fans when thermostat is satised
Case cleaning function for documentation of HACCP procedure
Rail heat control via day/night load or dew point
Door function
Control of two compressors
Control of night blinds
Light control
Heat thermostat
Integrated MODBUS communication with the option of
mounting a LonWorks communication card
Appliance examples
Contents
Introduction ....................................................................................................... 2
Operation ............................................................................................................ 4
Applications .....................................................................................................12
Connections .....................................................................................................17
Survey of functions ........................................................................................19
Operation ..........................................................................................................32
Menu survey .....................................................................................................33
Ordering ............................................................................................................39
Data .....................................................................................................................40

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Danfoss ADAP-KOOL AK-CT 200A and is the answer not in the manual?

Danfoss ADAP-KOOL AK-CT 200A Specifications

General IconGeneral
BrandDanfoss
ModelADAP-KOOL AK-CT 200A
CategoryControl Unit
LanguageEnglish

Related product manuals