AK-CC 550 Manual RS8EN502 © Danfoss 02-2010 5
Thermostat bands
Thermostatbandscanbeusedbeneciallyforapplianceswhere
dierentproducttypesarestoredwhichrequiredierenttem-
peratureconditions.Itispossibletochangebetweenthetwo
dierentthermostatbandsviaacontactsignalonadigitalinput.
Separate thermostat and alarm limits can be set for each thermo-
stat band – also for the product sensor.
Night setback of thermostat value
Inrefrigerationappliancestheremaybebigloaddierences
betweentheshop’sopeningandclosinghours,especiallyifnight
lids/blindsareused.Thethermostatreferencemayberaisedhere
withoutithavinganyeectontheproducttemperature.
Change-overbetweendayandnightoperationcantakeplace,as
follows:
•viaanexternalswitchsignal.
•viaasignalfromthedatacommunicationsystem.
Product sensor
AseparateoptionalproductsensorS6,whichmaybeplaced
in the appliance, can also be used and which can register and
monitor the temperature in the warmest part of the appliance.
There are separate alarm limits and time delays for the product
sensor.
Appliance cleaning
Thisfunctionmakesiteasyfortheshop’sstatocarryouta
cleaning of the appliance according to a standard procedure.
Appliancecleaningisactivatedviaasignal–asaruleviaakey
switch placed on the appliance.
Appliancecleaningiscarriedoutviathreephases:
1-attherstactivationtherefrigerationisstopped,butthefans
keeponoperatinginordertodefrosttheevaporators.”Fan”is
shown on the display.
2-atthesecondactivationthefansarealsostoppedandthe
appliancecannowbecleaned.”OFF”isshownonthedisplay.
3-Atthethirdactivationrefrigerationisrecommenced.The
displaywillshowtheactualappliancetemperature,(o97
setting).
Whenappliancecleaningisactivatedacleaningalarmistrans-
mitted to the normal alarm recipient. A later processing of these
alarms will document that the appliance has been cleaned as
often as planned.
Alarm monitoring
There are no temperature alarms during appliance cleaning.
- + + °C
1 ÷ + Fan
2 ÷ ÷ O
3 + + °C