Menu selection Meaning Factory setting
LOG TIME Time interval between collection points of temperature history in minutes. The history
graphs always show the 60 last collection points, which means that the graphs can dis-
play history from 1 hour up to 60 hours ago.
(The function is not active if there is an active alarm).
1M
(range: 1M / 60M)
BRINE TIME ON The brine pump starts the set number of seconds before the compressor. Applies at start
of heat pump.
30S
(range: 10S / 90S)
BRINE TIME OFF The brine pump stops the set number of seconds after the compressor. Applies at stop of
heat pump.
30S
(range: 10S / 60S)
SYSTEM
Menu selection Meaning Factory setting
HEAT SOURCE GROUND OR ROCK
OUTSIDE AIR
(BRINE SOLUTION, DIRECT EVAP.)
B/W
COOLING PASSIVE COOLING
( , PASSIVE, INTEGRATED IN HP)
ACTIVE COOLING
( , PASSIVE/ACTIVE, ACTIVE)
ROOM SENSOR
(
, ON)
POOL
, ON
SHUNT GROUP
, ON
BUFFER TANK (See separate instruction
for buffer tank)
BUFFER TANK
SYSTEM SHUNT
2ND H.C SHUNT
ADDITION OPTIMUM
( , CIRC. PUMP, TWO WAY VALVE)
HGW
( , ON)
FLOW SENSOR
( , ON)
Permanently ON or ON/ depending on
model.
CURRENT LIMITER
( , ON)
PHASE FAULT
( , PHASE READING)
Installation Guide Domestic heat pumps
Danfoss Heating Solutions VMGFQ102
47