RI8KX753 09-2016
084R9986
INSTRUCTIONS
EKC 202D / EKC 302D
084R9986
Data communication
Type:
Pt 1000 (1000 Ω /0°C ) /
Ptc 1000 Type
NTC-M2020 (5000 Ω / 25°C)
( o06)
Koordineret afrimning
Coordinated defrost
t
amb
= 0 - +55°C
230 V a.c.
50/60 Hz
2.5 VA
10 V < U < 256 V
LON RS485:
MOD-bus
EKC 202D EKC 302D
LON RS485
EKC 302D
EKC 202D
IP 20
IEC60730
EKC 202D
DO1 8 (6) A & (5 FLA, 30 LRA)
DO2 8 (6) A & (5 FLA, 30 LRA)
DO3 6 (3) A & (3 FLA, 18 LRA)
DO4** 4 (1) A, Min. 100 mA**
EKC 302D
DO1
10 (6) A & (5 FLA, 30 LRA) 1)
16 (8) A & (10 FLA, 60 LRA) 2)
DO2
6 (3) A & (3 FLA, 18 LRA) 1)
10 (6) A & (5 FLA, 30 LRA) 2)
DO3
6 (3) A & (3 FLA, 18 LRA) 1)
10 (6) A & (5 FLA, 30 LRA) 2)
DO4** 4 (1)A Min. 100 mA**
* EKC 202D: DO1 and DO2 are 16 A relays. DO3 and DO4 are 8 A relays. Above
max. load must be kept.
EKC 302D: DO1 is 20 A relay. DO2 and DO3 are 16 A relays. DO4 is a 10 A
relay. The max. load listed above must be observed when connecting without zero-
crossing control. When connecting with zero-crossing control, the load must be
increased to the value indicated by 2)
** Gold plating ensures make function with small contact loads
1) With external relay (c70=ON) (zero-crossing control disabled)
2) Without external relay (c70=OFF) (zero-crossing control enabled)