6
WIRING CONVERSIONS
Wiring conversions can be used when replacing the following programmers
with the FP715. Some time controls are connected differently depending on
the type of system they are controlling. Consult the column headed “NOTE
Table A
DANFOSS RANDALL
FP715, CP715
(PUMPED)
MAINS
DHW
OFF
HTG
OFF
DHW
ON
NL12 3
DANFOSS RANDALL 922/972 NL14 3
DANFOSS RANDALL 4033 7653 4
DANFOSS RANDALL SET 5 NL36 1
HORSTMANN 423, AMETHYST 7 & 10 2,3 1 4 6 5
HORSTMANN 424 GEM 2,3 1,10 6 9 4
HORSTMANN LEUCITE 423 & 424 2148
3
HORSTMANN 425 DIADEM NL36 1
HORSTMANN 525 & 527 NL36 1
HONEYWELL ST669 NL74 6
HONEYWELL ST6300 & ST6400 NL12 3
PEGLER SUNVIC SP50/SP100 NL14 2
POTTERTON EP2000, EP3000 NL12 3
RANDALL TSR3+3 3,6 7 2 5 1
RANDALL 3033 1,7 6 5 3 4
RANDALL 702 NL42 3
SANGAMO FORM 1 410 & 414 4,5 6 2 7 1
SANGAMO S409/1 N,1,3 L - - 2