5. Maintain servo pressure differential between 1-2 bar [14-29 psi] during this step. Slowly thread the
servo cylinder on the M5 side in until the system pressure differential starts to decrease. Continue
turning the servo cylinder in until the system delta pressure results in no machine movement.
System delta pressure (ports MA to MB or MC to MD) between 3-4 bar typically does not cause
machine movement. If service of a pump is not performed on the machine, validation of machine
movement must be checked upon machine start up.
6. To complete setting neutral, repeat steps 1-5 but stroke the pump in the opposite direction by
turning the eccentric screw in the opposite direction, or by supplying current to solenoid C2. Reverse
gauge locations (M4 for M5, MB for MA etc.) from those stated above since the pump is now stroking
the other direction.
7. Set neutral for the rear pump by repeating steps 1-6 on the rear pump. Remember that the rear pump
is a mirror image of the front pump and therefore the locations of the servo gauge ports (M4/M5) and
the control solenoids (C1/C2) are opposite.
8. Remove all gauges and replace gauge port plugs. You can find wrench sizes and plug torques in Plug
size and torque chart on page 66
Service Manual
H1 45/53/60/68 Tandem Closed Circuit Axial Piston Pumps
Adjustments
46 |
©
Danfoss | June 2018 520L0928 | AX00000103en-US0303

Table of Contents

Other manuals for Danfoss H1

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Danfoss H1 and is the answer not in the manual?

Danfoss H1 Specifications

General IconGeneral
BrandDanfoss
ModelH1
CategoryWater Pump
LanguageEnglish

Related product manuals