EasyManuals Logo
Home>Danfoss>Accessories>KPP Pulse Pickup

Danfoss KPP Pulse Pickup User Manual

Danfoss KPP Pulse Pickup
20 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #7 background imageLoading...
Page #7 background image
Technical Information KPP PPU
11029257 • Rev BB • July 2013 7
Dimensions
Common Lead Wire Conguration (at end)
Non-adjustable Wire Conguration (conical end)
Conguration Used Only for Series 51 and 51-1 Cartridge Motors (conical end)
Dimensions in mm [inches].
Speed ring
9/16-18 UNF-2A THD (all models)
O-ring
P/N 9004201-3700
Locking nut
P/N K13988
Torque lock nut
13 ± 1.3 N•m
[10 ± 1 lbf•ft]
57.15 [2.25]
Red
White
Black
Green
3520
1.52 [0.060] maximum
Air gap approximately
1/2 to 1 turns of thread
Orientation notch
22.9 [.90]
1.52 [0.060] maximum
Air gap approximately
2-3 turns of thread
Speed ring
9/16-18 UNF -2A THD
3521
45.5 [1.79]
02.7 [0.11]
8.99 [0.35]
1.52 [0.060] maximum
Speed ring
3522