AN30483496955101-000102 RX1-S V24
1. Installation Steps
User Guide can be downloaded from: heating.danfoss.com.
Instructions below include thermostat installation and pairing
toRX1-S V2.
1. Installation must be done by an authorised
electrician.
2. The room thermostat should be installed at approx.
1.5 m above oor and where the eects of sunlight,
draught or other heat sources (eg. TV’s) are avoided,
see g. 1 on page 44.
3. Decide location of RX1-S V2 receiver, ensuring a
minimum space of 30cm from boiler housing. There
must be no large metal objects, such as boiler cases
or other large appliances, in line of sight between the
thermostat and the receiver as this will prevent RF
communication, see g. 1 on page 44.
4. Remove and mount RX1-S V2 back plate direct to wall
or on wall box, and wire as required for application,
see g. 2 on page 44.
5. Locate hooks at top of RX1-S V2 into top of back plate
and lower into position and tighten retaining screw.
Switch on mains power to start RF pairing.
6. Loosen lower retaining screw of thermostat and
carefully remove back plate, see g. 3 on page 44.
7. Insert 2x AA Alkaline batteries to front part taking care
to insert correctly as indicated. Check RF connection
between Thermostat and RX1-S V2 Receiver before
xing in nal position, see 3.1, RF Pairing.
Installation Guide
EN