AN30483496955101-000102 RX1-S V26
3.2 Legacy - RF Pairing
Use this guide when replacing the RF receiver only,
where existing room thermostat is reused.
If both products are changed follow normal pairing
procedure, see 3.1 RF Pairing, page 5.
1. Ensure the power to RX1-S V2 receiver is switched on
and batteries are inserted into the thermostat.
2. Put the thermostat in pairing mode, see thermostat
installation guide.
3. Press and hold the PROG button on the RX1-S V2 until
the PROG button LED (green) turns on.
4. If pairing is successful RF icon on thermostat will stop
ashing and remain on.
5. If pairing is not successful, try moving thermostat to
alternative position and retry.
4. Thermostat Error Codes
Display Description
E1 Sensor Failure
EE EEPROM Failure
Lo Measured temperature below 0 °C
Hi Measure temperature above 50 °C
E3 RF Pairing Failed
E4 RF Signal Lost
E5 RF Hardware Failure
E6 Real Time Clock Failure(TP5001RF Only)