25
Warnings
TPOne monitors several conditions and will provide warnings when
necessary, these messages will be shown at the top of the display.
If the condition that has created the warning has been corrected
then the message can be cancelled by selecting Clear Warnings
in the TPOne menu. Where more than one warning has occurred
the most recent will be shown on the display. All warnings can be
viewed and cleared in the Clear Warnings menu.
Frost Risk This will be displayed if the TPOne monitors a
temperature of below 5
o
C. TPOne will call for
heat if this occurs but if the heat source is faulty
then risk of frost damage may still occur. The
heating system should be checked to conrm it is
operating correctly
Low Heat If set mode temperature is not reached within
2 hours then TPOne will warn of Low Heat. The
heating system should be checked to conrm it is
operating correctly
Service Due Where the TPOne Service Interval timer has been
set this warning will be shown when the timer has
expired. Contact the property owner or landlord
to arrange the boiler safety mainantance.
see page 21
Heat
Reduced
Where the TPOne Service Interval timer has been
set this warning will show after the timer has
expired and will indicate that heating has been
reduced for your safety until a boiler service has
been completed. Contact the property owner or
landlord to arrange the boiler safety mainantance.
see page 21
High Floor
Temperature
Where a oor limit temperature sensor has been
tted if the oor temperature exceeds the set limit
this warning will show. If the oor temperature
has reduced to a safe level the TPOne will continue
to control heating but the reason for the overheat
may still exist. The oor heating system should be