5. Technical Data
5.1. Technical Data
Nomen-
cla-
ture
1)
Parameter TripleLynx
8 kW
TripleLynx
10 kW
TripleLynx
12.5 kW
TripleLynx
15 kW
AC
P
ac,r
Nom. power AC 8000 W 10000 W 12500 W 15000 W
Reactive power range 0-4.8 kVAr 0-6.0 kVAr 0-7.5 kVAr 0-9.0 kVAr
V
ac,r
AC voltage range (P-N) 3 x 230 V ± 20 % 3 x 230 V ± 20 % 3 x 230 V ± 20 % 3 x 230 V ± 20 %
Nominal current AC 3 x 12 A 3 x 15 A 3 x 19 A 3 x 22 A
I
acmax
Max. current AC 3 x 12 A 3 x 15 A 3 x 19 A 3 x 22 A
AC current distortion (THD
%)
< 4 % < 5 % < 5 % < 5 %
cosphi
ac,r
Power factor at 100 % load > 0.98 > 0.99 > 0.99 > 0.99
Controlled power
factor range
0.8 over-excited
0.8 under-excited
0.8 over-excited
0.8 under-excited
0.8 over-excited
0.8 under-excited
0.8 over-excited
0.8 under-excited
“Connecting” power loss 10 W 10 W 10 W 10 W
Night-time power loss (off
grid)
< 5 W < 5 W < 5 W < 5 W
f
r
Grid frequency 50 ± 5 Hz 50 ± 5 Hz 50 ± 5 Hz 50 ± 5 Hz
DC
Nominal power DC 8250 W 10300 W 12900 W 15500 W
Max. recommended PV
power at STC
2)
9500 Wp 11800 Wp 14700 Wp 17700 Wp
V
dc,r
Nominal voltage DC 700 V 700 V 700 V 700 V
V
mppmin
-
V
mppmax
MPP voltage - nominal
power
3)
345-800 V 430-800 V 358-800 V 430-800 V
MPP efficiency 99.9 % 99.9 % 99.9 % 99.9 %
V
dcmax
Max. DC voltage 1000 V 1000 V 1000 V 1000 V
V
dcstart
Turn on voltage DC 250 V 250 V 250 V 250 V
V
dcmin
Turn off voltage DC 250 V 250 V 250 V 250 V
I
dcmax
Max. current DC 2 x 12 A 2 x 12 A 3 x 12 A 3 x 12 A
Max. short circuit current
DC at STC
2 x 12 A 2 x 12 A 3 x 12 A 3 x 12 A
Min. on grid power 20 W 20 W 20 W 20 W
Efficiency
Max. efficiency 97.9 % 98 % 98 % 98 %
Euro efficiency, V at
dc,r
97.0 % 97.0 % 97.3 % 97.4 %
Other
Dimensions (L,W,H) 700 x 525 x 250
mm
700 x 525 x 250
mm
700 x 525 x 250
mm
700 x 525 x 250
mm
Mounting recommendation Wall bracket Wall bracket Wall bracket Wall bracket
Weight 35 kg 35 kg 35 kg 35 kg
Acoustic noise level
4
56 dB(A) 56 dB(A) 56 dB(A) 56 dB(A)
MPP trackers 2 2 3 3
Operation temperature
range
-25..60 °C -25..60 °C -25..60 °C -25..60 °C
Nom. temperature range -25..45 °C -25..45 °C -25..45 °C -25..45 °C
Storage temperature -25..60 °C -25..60 °C -25..60 °C -25..60 °C
Overload operation Change of operat-
ing point
Change of operat-
ing point
Change of operat-
ing point
Change of operat-
ing point
Overvoltage category AC Class III Class III Class III Class III
Overvoltage category DC Class II Class II Class II Class II
PLA
5)
Included Included Included Included
Reactive power TLX+ and TLX Pro
+
TLX+ and TLX Pro
+
TLX+ and TLX Pro
+
TLX+ and TLX Pro
+
Functional Safety
Safety (protective class) Class I Class I Class I Class I
PELV on the communication
and control card
Class II Class II Class II Class II
Islanding detection - loss of
mains
Three-phase moni-
toring (ROCOF)
Three-phase moni-
toring (ROCOF)
Three-phase moni-
toring (ROCOF)
Three-phase moni-
toring (ROCOF)
Voltage magnitude Included Included Included Included
Frequency Included Included Included Included
DC content of AC current Included Included Included Included
Insulation resistance Included Included Included Included
RCMU - Type B Included Included Included Included
Indirect contact protection Yes (class I, groun-
ded)
Yes (class I, groun-
ded)
Yes (class I, groun-
ded)
Yes (class I, groun-
ded)
Short circuit protection Yes Yes Yes Yes
Table 5.1: Specifications