TS715SI
10
GB
(Applies only to 230 volt models)
Wiring conversions for other timeswitches which can be replaced
with the Danfoss TS715-Si, refer to the second part of the table. If in
any doubt, please contact our Technical Services Department before
proceeding with the replacement.
7.0 Wiring Conversions
DANFOSS RANDALL
TS715-Si
MAINS
NL
NL
The existing wallplate may be used when replacing the following, but the wiring
link between L & COM terminals of wallplate.
ACL LS111, LS711, LP111 & LP711 N L
DRAYTON TEMPUS ONE & TEMPUS TWO N L
LANDIS & GYR RWB3 N L
LANDIS & GYR RWB30 N L
The TS75/TS15 wallplate must be used to replace the existing wallplate when repl
mains voltage systems, fi t wire link between terminal 1 & L of wallplate.
GRASSLIN 45, 45A, 45E 2 1
HONEYWELL ST6100 N L
HORSTMANN 423 PEARL, EMERALD & TOPAZ N L
HORSTMANN KMK2A YMK2 3 4
HORSTMANN 425 CORONET N L
DANFOSS RANDALL 911 N L
DANFOSS RANDALL 103, 103E, 103E5 & 103E7 5 6
RANDALL 3020 1,7 6
DANFOSS RANDALL SET1 N L
RANDALL TSR2 3 2
PEGLER SUNVIC SP20 & SP25/30 N L
POTTERTON MYSON EP4001 N L