MG.20.B6.02 – VLT is a registered Danfoss trademark
105
VLT
®
2000 Series
Section 1 Section 2 Section 3
Factory settings and service
References
200 FREQ RANGE
2
)
120 Hz
201 MIN. FREQUENCY
2,S
)
0
202 MAX. FREQUENCY
2,S
)
50 Hz
203 JOG FREQUENCY
2,S
)
10 Hz
204 DIG. REF. TYPE
S
)
SUM
205 DIGITAL REF. 1
2,S
)
0
206 DIGITAL REF. 2
2,S
)
0
207 DIGITAL REF. 3
2,S
)
0
208 DIGITAL REF. 4
2,S
)
0
209 CURRENT LIMIT
2,S
)
Depending on unit
210 LOW FREQ WARN
2,S
)
0 Hz
211 HI FREQ WARN
2,S
)
120 Hz (from 200)
213 HI CURR WARN
2,S
)
I
VLT,MAX
(from 209)
215 RAMP UP TIME 1
2,S
)
5 s
216 RAMP DOWN TIME 1
2,S
)
5 s
218 ALT: DOWN RAMP 1
2,s
)
1 s
224 CARRIER FREQ.
2,S
)
4.5 KhZ
230 SPEED UP/DOWN
S
)
DISABLE
Functions and timers
300 BRAKE OPTION
S
)
NOT APPLIED
306 DC-BRAKE TIME
2,S
)
0 s
307 DC-BRK FREQ
2,S
)
1 Hz
308 DC-BRK VOLTAGE
2,S
)
10 V
309 RESET MODE
S
)
MANUAL
310 TRIP DLY@C.LIM
S
)
INFINITE
315 MOTOR THERMAL
2,S
)
PROTECT-OFF
Operation and display
000 LANGUAGE
S
)
ENGLISH
001 MENU SETUP
S
)
SETUP 1
002 MENU SET COPY
DO NOT COPY
003 LOCAL/REMOTE
S
)
REMOTE
004 LOCAL
S
)
005 VALUE AT MAX
S
)
1000
006 LOCAL RESET
S
)
ENABLE
007 LOC START/STOP
S
)
ENABLE
008 LOCAL FWD/REV
S
)
DISABLE
009 LOCAL JOG
S
)
ENABLE
010 LOC REFERENCE
S
)
ENABLE
013 DATACHG.LOCK
NOT LOCKED
Load and motor
101 SPEED CONTROL
2, S
)
SLIP COMP
102 CURRENT LIMIT
S
)
PROGRAM SET
103 MOTOR POWER
2
)
NOM. SIZE
104 MOTOR VOLTAGE
2
)
Depending on unit
105 MOTOR FREQ
2
)
50 Hz
107 MOTOR CURRENT
2,S
)
Depending on unit
108 MOTOR MAG.AMP.
2,S
)
Depending on unit
109 START VOLTAGE
2,S
)
Depending on unit
110 START COMP
2,S
)
0
111 U/F RATIO
2,S
)
Depending on unit
112 SLIP COMPENSATION
2,S
)
Depending on unit
114 FEEDBACK TYPE
S
)
CURRENT
119 FEEDFWD FACTR
2,S
)
100%
120 CONTRL RANGE
2,S
)
100%
121 PROPRT/L GAIN
2,S
)
0.01
122 INTEGRAL TIME
2,S
)
OFF
125 FEEDBACK SCALE
100%
2
) Can be changed in both setups
S
) Can be changed i Start mode
(running motor)
Inputs and outputs
402 INPUT 18
S
)
START
403 INPUT 19
S
)
REVERSING
404 INPUT 27
S
)
MTR.COAST not
405 INPUT 29
S
)
JOG
408 LOG OUTPUT 46
2,S
)
UNIT READY
409 RELAY OUT 01
2,S
)
UNIT READY
411 ANALOG REF TYPE
2,S
)
LINEAR
412 INPUT #53
2,S
)
0 - 10 VDC
413 INPUT #60
2,S
)
0-20 mA
Serial data interface
500 ADDRESS
01
501 BAUD RATE
1200 K
502 DATA READ-OUT
S
)
REFERENCE%
503 COASTING
S
)
LOGICAL OR
504 Q-STOP
S
)
LOGICAL OR
505 DC-BRAKE
S
)
LOGICAL OR
506 START
S
)
LOGICAL OR
507 DIRECTION
S
)
DIGITAL
508 RESET
S
)
LOGICAL OR
509 SETUP SELECT
S
)
LOGICAL OR
510 SPEED SELECT
S
)
LOGICAL OR
511 BUS JOG 1
S
)
10 Hz
514 BUS BIT 4
S
)
QUICK STOP
516 BUS REFERENCE
S
)
0
517 STORE DATA
S
)
OFF
Service and display
606 TOTAL OP HRS.
607 RUNNING HRS.
608 NO. POWERUPS
609 NO. OVERTEMPS
610 NO. OVERVOLTS