414
Minimum feedback, FB
MIN
(Min. feedback)
Value:
-100,000.000 - par. 415 FB
MAX
0.000
Function:
Parameter 414 Minimum feedback, FB
MIN
and 415
Maximum feedback, FB
MAX
are used to scale the dis-
play text to make it show the feedback signal in a
process unit proportionally to the signal on the input.
Description of choice:
Set the value to be shown on the display as the mini-
mum feedback signal value on the selected feedback
input (parameters 308/314 Analog inputs).
415
Maximum feedback, FB
MAX
(Max. feedback)
Value:
FB
MIN
- 100,000.000
1500.000
Function:
See description of parameter 414 Minimum feedback,
FB
MIN
.
Description of choice:
Set the value to be shown on the display when the
maximum feedback has been obtained on the selected
feedback input (parameter 308/314 Analog inputs).
416 Process units
(REF/FEEDB. UNIT)
Value:
No unit (No unit) [0]
% (%) [1]
ppm (ppm) [2]
rpm (rpm) [3]
bar (bar) [4]
Cycles/min. (CYCLE/MIN.) [5]
Pulses/sec. (PULSE/SEC.) [6]
Units/sec. (UNITS/SEC.) [7]
Units/min. (UNITS/MIN.) [8]
Units/h (Units/h) [9]
°C (°C) [10]
Pa (pa) [11]
l/s (l/s) [12]
m
3
/s (m3/s) [13]
l/min. (l/min.) [14]
m
3
/min. (m3/min) [15]
l/h (l/h) [16]
m
3
/h (m3/h) [17]
kg/sec. (kg/sec.) [18]
kg/min. (kg/min.) [19]
kg/hour (kg/h) [20]
tons/min. (T/min) [21]
tons/hour (T/h) [22]
Meters (m) [23]
Nm (nm) [24]
m/sec. (m/sec.) [25]
m/min. (m/min) [26]
°F (°F) [27]
In wg (in wg) [28]
gal/sec. (gal/sec.) [29]
ft
3
/sec. (ft3/sec.) [30]
gal/min. (gal/min) [31]
ft
3
/min. (ft3/min) [32]
gal/h (gal/h) [33]
ft
3
/h (ft3/h) [34]
lb/sec. (lb/sec.) [35]
lb/min. (lb/min.) [36]
lb/hour (lb/h) [37]
lb ft (lb ft) [38]
ft/s (ft/s) [39]
ft/min. (ft/min.) [40]
psi (psi) [41]
Function:
Select which of the different units are to be shown on
the display. The unit is read out if an LCP control unit
can be connected, and if Reference [unit] [2] or Feed-
back [unit] [3] has been selected in one of parameters
009-012 Display readout, and in display mode. The unit
is used in Closed-loop also as a unit for minimum/
maximum reference and minimum/maximum feed-
back.
VLT
®
2800 Series
= factory setting, () = display text, [] = value for use in communication via serial communication port
MG.27.A2.22 - VLT
®
is a registered Danfoss trademark 71
Programming

Table of Contents

Other manuals for Danfoss VLT 2800 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Danfoss VLT 2800 Series and is the answer not in the manual?

Danfoss VLT 2800 Series Specifications

General IconGeneral
BrandDanfoss
ModelVLT 2800 Series
CategoryDC Drives
LanguageEnglish

Related product manuals