349 Speed comp delay
(SPEED COMP DELAY)
Value:
0 ms - 100 ms
10 ms
Function:
In this parameter the user can set the SYSTEM's delay
time (Sensor, PLC, etc.). If you are running speed-
compensated stop, the delay time at different frequen-
cies has a major influence on the way in which you
stop.
Description of choice:
The factory setting is 10 ms. This means that it is as-
sumed that the total delay from the Sensor, PLC and
other hardware corresponds to this setting.
NB!
Only active for speed-compensated stop.