MG.50.Q2.02 – VLT is a registered Danfoss trade mark
VLT
®
3000 to 5000 converter
Mapping list
The below listed VLT 3000 parameters in the left column have the corresponding VLT 5000 parameters as
shown in the right column. Please be notify that the opposite is not the case. the 5000 series using the LCP.
V
LT 3000 Series
V
LT 5000 series
000 Language Select 001 Language
001 Setup Selection Operation 004 Active Setup
002 Setup Copy 006 Copying of Setups
003 Operation Site 002 Local/remote Control
004 Local reference Not available via serial com.
005 Display Value 008 Display Scaling of Motor Frequency
006 Local Reset 017 Local Reset of Trip
007 Local stop Not available via serial com.
008 Local reversing Not available via serial com.
009 Local Jogging 015 Local Jog
010 Local reference Not available via serial com.
011 Reset Energy Counter 618 Reset of kWh Counter
012 Reset Hour Counter 619 Reset of Hour-Run Counter
014 Power-Up Mode 019 Operating State at Power-Up, Local
015 Set-up Selection 005 Programming Set-up
100 Load 101 Torque characteristics
101 Speed Control 100 Configuration
102 Current Limit Control 308, 311 and 314, Analogue input function
103 Motor power 102 Motor power
104 Motor voltage 103 Motor voltage
105 Motor frequency 104 Motor frequency
106 Automatic motor adaption 107 Automatic motor adaption
107 Motor current 105 Motor current
108 Motor magnetizing current No valid parameter
109 Start voltage No valid parameter
110 Start compensation No valid parameter
111 U/f ratio No valid parameter
112 Slip compensation No valid parameter
113 Negative slip compensation No valid parameter
114 Feedback type 308, 311 and 314, Analogue input function
115 Display Value at min. Feedback 414 Minimum Feedback
116 Display Value at max. Feedback 415 Maximum Feedback
117 Feedback Type 416 Reference/feedback Unit
121 Proportional Gain 440 Process PID Proportional Gain
122 Integral Time 441 Process PID Integral Time
123 Differentiation Time 442 Process PID Differentiation Time
124 Low Pass Filter 444 Process PID Low Pass Filter
Mapping list

Other manuals for Danfoss VLT 3000 Series