VLT
®
5000 Series
General technical data
Mains supply (L1, L2, L3):
Supply voltage 200-240 V units ........................................................................ 3 x 200/208/220/230/240 V ±10%
Supply voltage 380-500 V units ................................................................ 3 x 380/400/415/440/460/500 V ±10%
Supply voltage 525-600 V units ............................................................................... 3 x 525/550/575/600 V ±10%
Supply voltage 525-690 V units ........................................................................ 3 x 525/550/575/600/690 V ±10%
Supply frequency ........................................................................................................................ 48-62 Hz +/- 1 %
See the section on special conditions in the Design Guide
Max imbalance of supply voltage:
VLT 5001-5011, 380-500 V and 525-600 V and VLT 5001-5006, 200-240 V .......... ±2.0% of rated supply voltage
VLT 5016-5062, 380-500 V and 525-600 V and VLT 5008-5027, 200-240 V .......... ±1.5% of rated supply voltage
VLT 5072-5552, 380-500 V and VLT 5032-5052, 200-240 V .................................. ±3.0% of rated supply voltage
VLT 5042-5602, 525-690 V ..................................................................................... ±3.0% of rated supply voltage
True Power factor (λ) ...................................................................................................... 0.90 nominal at rated load
Displacement Power Factor (cos ϕ) ............................................................................................. near unity (>0.98)
No. of switchings on supply input L1, L2, L3 .......................................................................... approx. 1 time/min.
See the section on special conditions in the Design Guide
VLT output data (U, V, W):
Output voltage ................................................................................................................ 0-100% of supply voltage
Output frequency VLT 5001-5027, 200-240 V ...................................................................... 0-132 Hz, 0-1000 Hz
Output frequency VLT 5032-5052, 200-240 V ........................................................................ 0-132 Hz, 0-450 Hz
Output frequency VLT 5001-5052, 380-500 V ...................................................................... 0-132 Hz, 0-1000 Hz
Output frequency VLT 5062-5302, 380-500 V ........................................................................ 0-132 Hz, 0-450 Hz
Output frequency VLT 5352-5552, 380-500 V ........................................................................ 0-132 Hz, 0-300 Hz
Output frequency VLT 5001-5011, 525-600 V ........................................................................ 0-132 Hz, 0-700 Hz
Output frequency VLT 5016-5052, 525-600 V ...................................................................... 0-132 Hz, 0-1000 Hz
Output frequency VLT 5062, 525-600 V .................................................................................. 0-132 Hz, 0-450 Hz
Output frequency VLT 5042-5302, 525-690 V ........................................................................ 0-132 Hz, 0-200 Hz
Output frequency VLT 5352-5602, 525-690 V ........................................................................ 0-132 Hz, 0-150 Hz
Rated motor voltage, 200-240 V units .............................................................................. 200/208/220/230/240V
Rated motor voltage, 380-500 V units ............................................................... 380/400/415/440/460/480/500 V
Rated motor voltage, 525-600 V units ............................................................................................ 525/550/575 V
Rated motor voltage, 525-690 V units ..................................................................................... 525/550/575/690 V
Rated motor frequency ............................................................................................................................ 50/60 Hz
Switching on output ................................................................................................................................. Unlimited
Ramp times .................................................................................................................................... 0.05-3600 sec.
Torque characteristics:
Starting torque, VLT 5001-5027, 200-240 V and VLT 5001-5552, 380-500 V ................................ 160% for 1 min.
Starting torque, VLT 5032-5052, 200-240 V .................................................................................. 150% for 1 min.
Starting torque, VLT 5001-5062, 525-600 V .................................................................................. 160% for 1 min.
Starting torque, VLT 5042-5602, 525-690 V .................................................................................. 160% for 1 min.
Starting torque ............................................................................................................................ 180% for 0.5 sec.
Acceleration torque ....................................................................................................................................... 100%
Overload torque, VLT 5001-5027, 200-240 V and VLT 5001-5552, 380-500 V,
VLT 5001-5062, 525-600 V, and VLT 5042-5602, 525-690 V ....................................................................... 160%
Overload torque, VLT 5032-5052, 200-240 V ............................................................................................... 150%
Arresting torque at 0 rpm (closed loop) ......................................................................................................... 100%
The torque characteristics given are for the frequency converter at the high overload torque level
(160%). At the normal overload torque (110%), the values are lower.
MG.51.A9.02 - VLT is a registered Danfoss trademark
10

Table of Contents

Other manuals for Danfoss VLT 5027

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Danfoss VLT 5027 and is the answer not in the manual?

Danfoss VLT 5027 Specifications

General IconGeneral
BrandDanfoss
ModelVLT 5027
CategoryDC Drives
LanguageEnglish

Related product manuals