VLT
®
5000 Series
Programming
Outputs terminal no. Relay
06
Relay
07
Relay 08 Relay
09
parameter 700 703 706 709
Value:
No function (NO OPERATION) [0] [0] [0] [0]
Control ready (CONTROL READY) [1] [1] [1] [1]
Ready signal (UNIT READY) [2] [2] [2] [2]
Ready - remote control (UNIT READY/REM CTRL) [3] [3] [3] [3]
Enable, no warning (ENABLE/NO WARNING) [4] [4] [4] [4]
Running (VLT RUNNING) [5] [5] [5] [5]
Running, no warning (RUNNING/NO WARNING) [6] [6] [6] [6]
Running within range, no warning (RUN IN RANGE/NO WARN) [7] [7] [7] [7]
Running at reference value, no warning(RUNONREF/NOWARN) [8] [8] [8] [8]
Fault (ALARM) [9] [9] [9] [9]
Fault or warning (ALARM OR WARNING) [10] [10] [10] [10]
Torque limit (TORQUE LIMIT) [11] [11] [11] [11]
Out of current range (OUT OF CURRENT RANGE) [12] [12] [12] [12]
Over I low (ABOVE CURRENT, LOW) [13] [13] [13] [13]
Under I high (BELOW CURRENT, HIGH) [14] [14] [14] [14]
Out of frequency range (OUT OF FREQ RANGE) [15] [15] [15] [15]
Over f low (ABOVE FREQUENCY LOW) [16] [16] [16] [16]
Under f high (BELOW FREQUENCY HIGH) [17] [17] [17] [17]
Out of feedback range (OUT OF FDBK RANGE) [18] [18] [18] [18]
Over feedback low (ABOVE FDBK, LOW) [19] [19] [19] [19]
Under feedback high (BELOW FDBK, HIGH) [20] [20] [20] [20]
Thermal warning (THERMAL WARNING) [21] [21] [21] [21]
Ready - no thermal warning (READY &NOTHERM WARN) [22] [22] [22] [22]
Ready - remote control - no therm. warn. (REM RDY&NO THERMWAR) [23] [23] [23] [23]
Ready - mains voltage within range (RDY NO OVER/UNDERVOL) [24] [24] [24] [24]
Reversing (REVERSE) [25] [25] [25] [25]
Bus ok (BUS OK) [26] [26] [26] [26]
Torque limit and stop (TORQUE LIMIT AND STOP) [27] [27] [27] [27]
Brake, no brake warning (BRAKE NO WARNING) [28] [28] [28] [28]
Brake ready, no fault (BRAKE RDY (NO FAULT)) [29] [29] [29] [29]
Brake fault (BRAKE FAULT (IGBT)) [30] [30] [30] [30]
Relay 123 (RELAY 123) [31] [31] [31] [31]
Mechanical brake control (MECH. BRAKE CONTROL) [32] [32] [32] [32]
Control word bit 11/12 (CTRL WORD BIT 11/12) [33] [33] [33] [33]
Extended mechanical brake control (EXT. MECH. BRAKE) [34] [34] [34] [34]
Safety interlock (SAFETY INTERLOCK) [35] [35] [35] [35]
Mains ON (MAINS ON) [50] [50] [50] [50]
Motor running (MOTOR RUNNING) [51] [51] [51] [51]
Function:
Description of choice:
For description of choice please see parameter 319.
Mains ON [50], has the same logical function
as Running [5].
Motor running [51], has the same logical function
as Mechanical brake control [32]
= factory setting. () = display text [] = value for use in communication via serial communication port
MG.51.A9.02 - VLT is a registered Danfoss trademark
163

Table of Contents

Other manuals for Danfoss VLT 5027

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Danfoss VLT 5027 and is the answer not in the manual?

Danfoss VLT 5027 Specifications

General IconGeneral
BrandDanfoss
ModelVLT 5027
CategoryDC Drives
LanguageEnglish

Related product manuals