4.4.2 1-** Load/Motor
Par.
No. #
Parameter description Default value 4-set-up FC 302
only
Change dur-
ing opera-
tion
Conver-
sion index
Type
1-0* General Settings
1-00 Configuration Mode null All set-ups TRUE - Uint8
1-01 Motor Control Principle null All set-ups FALSE - Uint8
1-02 Flux Motor Feedback Source [1] 24V encoder All set-ups x FALSE - Uint8
1-03 Torque Characteristics [0] Constant torque All set-ups TRUE - Uint8
1-04 Overload Mode [0] High torque All set-ups FALSE - Uint8
1-05 Local Mode Configuration [2] As mode par 1-00 All set-ups TRUE - Uint8
1-06 Clockwise Direction [0] Normal All set-ups FALSE - Uint8
1-1* Motor Selection
1-10 Motor Construction [0] Asynchron All set-ups FALSE - Uint8
1-2* Motor Data
1-20 Motor Power [kW] SR All set-ups FALSE -2 Uint32
1-21 Motor Power [HP] SR All set-ups FALSE -2 Uint32
1-22 Motor Voltage SR All set-ups FALSE 0 Uint16
1-23 Motor Frequency SR All set-ups FALSE 0 Uint16
1-24 Motor Current SR All set-ups FALSE -2 Uint32
1-25 Motor Nominal Speed SR All set-ups FALSE 67 Uint16
1-26 Motor Cont. Rated Torque SR All set-ups FALSE -1 Uint32
1-29 Automatic Motor Adaptation (AMA) [0] Off All set-ups FALSE - Uint8
1-3* Adv. Motor Data
1-30 Stator Resistance (Rs) SR All set-ups FALSE -4 Uint32
1-31 Rotor Resistance (Rr) SR All set-ups FALSE -4 Uint32
1-33 Stator Leakage Reactance (X1) SR All set-ups FALSE -4 Uint32
1-34 Rotor Leakage Reactance (X2) SR All set-ups FALSE -4 Uint32
1-35 Main Reactance (Xh) SR All set-ups FALSE -4 Uint32
1-36 Iron Loss Resistance (Rfe)SRAll set-upsFALSE-3Uint32
1-37 d-axis Inductance (Ld) SR All set-ups x FALSE -4 Int32
1-39 Motor Poles SR All set-ups FALSE 0 Uint8
1-40 Back EMF at 1000 RPM SR All set-ups x FALSE 0 Uint16
1-41 Motor Angle Offset 0 N/A All set-ups FALSE 0 Int16
1-5* Load Indep. Setting
1-50 Motor Magnetisation at Zero Speed 100 % All set-ups TRUE 0 Uint16
1-51 Min Speed Normal Magnetising [RPM] SR All set-ups TRUE 67 Uint16
1-52 Min Speed Normal Magnetising [Hz] SR All set-ups TRUE -1 Uint16
1-53 Model Shift Frequency SR All set-ups x FALSE -1 Uint16
1-54 Voltage reduction in fieldweakening 0 V All set-ups FALSE 0 Uint8
1-55 U/f Characteristic - U SR All set-ups TRUE -1 Uint16
1-56 U/f Characteristic - F SR All set-ups TRUE -1 Uint16
1-58 Flystart Test Pulses Current 30 % All set-ups FALSE 0 Uint16
1-59 Flystart Test Pulses Frequency 200 % All set-ups FALSE 0 Uint16
1-6* Load Depen. Setting
1-60 Low Speed Load Compensation 100 % All set-ups TRUE 0 Int16
1-61 High Speed Load Compensation 100 % All set-ups TRUE 0 Int16
1-62 Slip Compensation SR All set-ups TRUE 0 Int16
1-63 Slip Compensation Time Constant SR All set-ups TRUE -2 Uint16
1-64 Resonance Dampening 100 % All set-ups TRUE 0 Uint16
1-65 Resonance Dampening Time Constant 5 ms All set-ups TRUE -3 Uint8
1-66 Min. Current at Low Speed 100 % All set-ups x TRUE 0 Uint8
1-67 Load Type [0] Passive load All set-ups x TRUE - Uint8
1-68 Minimum Inertia SR All set-ups x FALSE -4 Uint32
1-69 Maximum Inertia SR All set-ups x FALSE -4 Uint32
1-7* Start Adjustments
1-71 Start Delay 0.0 s All set-ups TRUE -1 Uint8
1-72 Start Function [2] Coast/delay time All set-ups TRUE - Uint8
1-73 Flying Start [0] Disabled All set-ups FALSE - Uint8
1-74 Start Speed [RPM] SR All set-ups TRUE 67 Uint16
1-75 Start Speed [Hz] SR All set-ups TRUE -1 Uint16
1-76 Start Current 0.00 A All set-ups TRUE -2 Uint32
1-8* Stop Adjustments
1-80 Function at Stop [0] Coast All set-ups TRUE - Uint8
1-81 Min Speed for Function at Stop [RPM] SR All set-ups TRUE 67 Uint16
1-82 Min Speed for Function at Stop [Hz] SR All set-ups TRUE -1 Uint16
1-83 Precise Stop Function [0] Precise ramp stop All set-ups FALSE - Uint8
1-84 Precise Stop Counter Value 100000 N/A All set-ups TRUE 0 Uint32
1-85 Precise Stop Speed Compensation Delay 10 ms All set-ups TRUE -3 Uint8
1-9* Motor Temperature
1-90 Motor Thermal Protection [0] No protection All set-ups TRUE - Uint8
1-91 Motor External Fan [0] No All set-ups TRUE - Uint16
1-93 Thermistor Resource [0] None All set-ups TRUE - Uint8
1-95 KTY Sensor Type [0] KTY Sensor 1 All set-ups x TRUE - Uint8
1-96 KTY Thermistor Resource [0] None All set-ups x TRUE - Uint8
1-97 KTY Threshold level 80 °C 1 set-up x TRUE 100 Int16
VLT
®
AutomationDrive FC 300 Operating
Instructions
4 How to Programme
MG.33.AG.02 - VLT
®
is a registered Danfoss trademark
73
4

Other manuals for Danfoss VLT AutomationDrive FC 301

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Danfoss VLT AutomationDrive FC 301 and is the answer not in the manual?

Danfoss VLT AutomationDrive FC 301 Specifications

General IconGeneral
BrandDanfoss
ModelVLT AutomationDrive FC 301
CategoryDC Drives
LanguageEnglish

Related product manuals