Mains Supply 3 x 380 - 500 V AC
FC 302
P250 P315 P355 P400
High/ Normal Load* HO NO HO NO HO NO HO NO
Typical Shaft output at 400 V
[kW]
250 315 315 355 355 400 400 450
Typical Shaft output at 460 V
[hp]
350 450 450 500 500 600 550 600
Typical Shaft output at 500 V
[kW]
315 355 355 400 400 500 500 530
Enclosure IP21 E1 E1 E1 E1
Enclosure IP54 E1 E1 E1 E1
Enclosure IP00 E2 E2 E2 E2
Output current
Continuous
(at 400 V) [A]
480 600 600 658 658 745 695 800
Intermittent (60 sec overload)
(at 400 V) [A]
720 660 900 724 987 820 1043 880
Continuous
(at 460/500 V) [A]
443 540 540 590 590 678 678 730
Intermittent (60 s overload)
(at 460/500 V) [A]
665 594 810 649 885 746 1017 803
Continuous kVA
(at 400 V) [kVA]
333 416 416 456 456 516 482 554
Continuous kVA
(at 460 V) [kVA]
353 430 430 470 470 540 540 582
Continuous kVA
(at 500 V) [kVA]
384 468 468 511 511 587 587 632
Max. input current
Continuous
(at 400 V ) [A]
472 590 590 647 647 733 684 787
Continuous
(at 460/500 V) [A]
436 531 531 580 580 667 667 718
Max. cable size, mains, motor
and load share [mm
2
(AWG
2)
)]
4x240
(4x500 mcm)
4x240
(4x500 mcm)
4x240
(4x500 mcm)
4x240
(4x500 mcm)
Max. cable size, brake [mm
2
(AWG
2)
)
2 x 185
(2 x 350 mcm)
2 x 185
(2 x 350 mcm)
2 x 185
(2 x 350 mcm)
2 x 185
(2 x 350 mcm)
Max. external mains fuses [A]
1
700 900 900 900
Estimated power loss
at 400 V [W]
4)
5059 6705 6794 7532 7498 8677 7976 9473
Estimated power loss
at 460 V [W]
4822 6082 6345 6953 6944 8089 8085 7814
Weight,
enclosure IP21, IP54 [kg]
263 270 272 313
Weight,
enclosure IP00 [kg]
221 234 236 277
Efficiency
4)
0.98
Output frequency 0 - 600 Hz
Heatsink overtemp. trip 110 °C
Power card ambient trip 75 °C
* High overload = 160% torque during 60 s, Normal overload = 110% torque during 60 s
Table 5.2
General Specifications
VLT
®
Automation Drive FC 300 Operating Instructions
96 MG33U402 - Rev. 2013-12-16
55

Table of Contents

Other manuals for Danfoss VLT AutomationDrive FC 302

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Danfoss VLT AutomationDrive FC 302 and is the answer not in the manual?

Danfoss VLT AutomationDrive FC 302 Specifications

General IconGeneral
BrandDanfoss
ModelVLT AutomationDrive FC 302
CategoryDC Drives
LanguageEnglish

Related product manuals