68930d (0x10D42) = 689.30 A
7.1.3.4 Bytes 8–9: Trip Code
See the chapter Trip Codes.
7.1.3.5 Bytes 10–11: Reserved
7.2 Explicit Messaging (Acyclic Operation)
This section provides information on objects, instances, attributes, and services for acyclic operation (explicit messaging).
All data is in little endian format.
7.2.1 Identity Object (Class 0x01)
Table 5: Supported Attributes for Identity Objects
7.2.2 Vendor-specific Objects
The EtherNet/IP Card supports vendor-specific classes 100, 101, 103, and 104.
7.2.2.1 Class 100 and 101 Objects (Read/Write)
Class 100 and 101 objects allow parameter values to be read from and written to the soft starter.
Class 100d (0x64): Parameters 1–99
Class 101d (0x65): Parameters 100–199
See the chapter Parameter Lists for more details.
7.2.2.2 Class 103 Objects (Read Only)
Class 103d (0x67) allows soft starter state information to be read from the soft starter.
N O T I C E
For models MCD6-0063B and smaller, current reported via communications is 10 times greater than the actual value shown on
the LCP.
AN353423548483en-000101 / 130R094520 | Danfoss A/S © 2020.12
Messaging
EtherNet/IP Card
Installation Guide