12
1007332 ISSUE 1
OWNER/INSTALLATION MANUAL
> 50 cm
Plant room
Heat Pump*
Wall
Heat Pump
Possible positions of HPP-i Heat Pump
Wall
Suitable opening
Heat Pump*
>70 cm
Heat Pump
>70 cm
>250 cm
Heat Pump
The red lines represent e air inlet area
* Controls are obscured by e wall� Connect to
optional remote control panel or Wi-Fi before
installing e heat pump in position�
Required free areas to provide air flow to and from heat
pumps when installed in an enclosed area or where
required to pass air rough a wall etc. Ensure e heat
pump is sealed against e wall so e outlet air cannot
recirculate. Ensure e hole rough e wall is sealed
to avoid e outlet air entering cavities and is smoo
so e outlet air is not restricted.
Free area is e available area rough which air can
pass rough a grille or louvres.
Minimum free areas m
2
Model Discharge area
HPP-i 8 0.169
HPP-i 12 0.169
HPP-i 16 0.169
HPP-i 18 0.229
HPP-i 24 0.301
HPP-i 30 0.301