11
1007332 ISSUE 1
3�0 INSTALLATION
Installation must only be attempted by competent
personnel.
3�1 POSITIONING AND AIRFLOW
The heat pump must be positioned in a well
ventilated area. Minimum distances between e heat
pump and any obstructions are shown below.
The heat pump must be fixed by M10 bolts to a
concrete base or mounting brackets. These must be
solid and fixed securely. Brackets must be corrosion
proof.
Do not block inlet or outlet grilles.
The heat pump absorbs energy from e air drawn
rough it. To function effectively e heat pump must
have access to e fresh air it needs.
Air must not recirculate. The air leaving e heat
pump must not be sucked back into e inlet.
Air must not be restricted. The air volume must not
be reduced.
The minimum required distances shown below
must be provided to minimise e risk of air
recirculation or restriction and reduction in
performance. Furer examples are shown on e
following page.
Important installation instruction
700mm
500 mm
2500 mm
700mm
Airflow - general principles