Chapter 3 – Printer Operation 21
3.7.3 Standard Calibration
The Standard Calibration can be performed using the DMXConfig Utility (see Section 3.5), or via the front
panel buttons (see Appendix B).
Once you have installed the DMXConfig utility and the printer is properly loaded with media, proceed with
calibration as follows:
1. Connect the host to the printer with a serial
or parallel cable.
2. Turn ON the printer.
3. Launch the DMXConfig utility.
4. Query the printer by using the Query Printer
toolbar button (top-left). This will connect to
the printer and get the current printer
settings.
5. Select the Sensor Calibration Tab and then
click the Media Calibration Wizard button.
When prompted click OK to start the
calibration wizard.
6. The Calibration Wizard will now prompt you to
Load Stock. Ensure that media is properly
loaded in the printer then close the printhead
and click OK.