EasyManuals Logo
Home>Dell>Server>PowerEdge R320

Dell PowerEdge R320 User Manual

Dell PowerEdge R320
143 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #62 background imageLoading...
Page #62 background image
3. Open the system.
4. Align the two notches on the metal standoffs with the slots on the side of the optical drive.
5. Slide the optical drive into the notches until it is seated firmly and the release latch snaps into place.
6. Connect the power cable.
7. Connect the data cable to the back of the drive and to the SATA connector on the system board.
NOTE: Route and secure the cables using the cable routing latch on the system chassis to prevent them from
being pinched or crimped.
8. Close the system.
9. If applicable, install the front bezel.
10. Reconnect the system to its electrical outlet and turn the system on, including any attached peripherals.
Cooling Fans
Your system supports:
Four cooling fans in a non-redundant power supply configuration.
Five cooling fans in a redundant power supply configuration.
NOTE: Fan 1 must be installed in a redundant power supply configuration.
NOTE: Hot-swap removal or installation of the fans is not supported.
NOTE: In the event of a problem with a particular fan, the fan number is referenced by the system’s management
software, allowing you to easily identify and replace the proper fan by noting the fan numbers on the cooling
shroud.
Removing A Cooling Fan
WARNING: Opening or removing the system cover when the system is on may expose you to a risk of electric
shock. Exercise utmost care while removing or installing cooling fans.
CAUTION: Many repairs may only be done by a certified service technician. You should only perform
troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or
telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your
warranty. Read and follow the safety instructions that came with the product.
CAUTION: Do not operate the system with the cover removed for a duration exceeding five minutes.
NOTE: The procedure for removing each fan is identical.
1. Turn off the system, including any attached peripherals, and disconnect the system from its electrical outlet.
2. Open the system.
3. Remove the cooling shroud or power distribution board shroud as applicable.
4. Disconnect the fan's power cable from the power cable connector on the system board or power distribution board
as applicable.
5. Lift the fan out of the cooling-fan bracket.
62

Table of Contents

Other manuals for Dell PowerEdge R320

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Dell PowerEdge R320 and is the answer not in the manual?

Dell PowerEdge R320 Specifications

General IconGeneral
Bus typeQPI
SteppingM1
FSB ParityNo
Scalability2S
Processor codeSR0LS
Processor cache10 MB
Processor cores4
Processor modelE5-2403
System bus rate6.4 GT/s
Processor seriesIntel Xeon E5-2400
Processor socketLGA 1356 (Socket B2)
Processor codenameSandy Bridge EN
Motherboard chipsetIntel C600
Processor frequency1.8 GHz
Processor cache typeSmart Cache
Processor lithography32 nm
Processor manufacturerIntel
Processor package size45 x 42.5 mm
Processor front side bus- MHz
Processor operating modes64-bit
ECC supported by processorYes
Supported instruction setsAVX
Thermal Design Power (TDP)80 W
Number of processors installed1
Maximum number of PCI Express lanes24
Memory types supported by processorDDR3-SDRAM
Memory channels supported by processorTriple
Memory clock speeds supported by processor800, 1066 MHz
Memory bandwidth supported by processor (max)25 GB/s
Maximum internal memory supported by processor375 GB
HDD size3.5 \
HDD speed7200 RPM
HDD capacity1000 GB
HDD interfaceSerial ATA
Optical drive typeDVD-RW
Total storage capacity2000 GB
Maximum storage capacity16 TB
Number of HDDs installed2
Memory slots6x DIMM
Internal memory4 GB
Memory clock speed1333 MHz
Maximum internal memory96 GB
Cabling technology10/100/1000Base-T(X)
PS/2 ports quantity-
USB 2.0 ports quantityUSB 2.0 ports have a data transmission speed of 480 Mbps, and are backwards compatible with USB 1.1 ports. You can connect all kinds of peripheral devices to them.
PCI Express slots version3.0
Power supply350 W
Compatible operating systemsMicrosoft Windows Server 2012 \\r Microsoft Windows Server 2012 Essentials\\r Microsoft Windows Server 2008 R2 \\r Novell SUSE Linux Enterprise Server\\r Red Hat Enterprise Linux
Sustainability certificatesENERGY STAR
Chassis typeRack (1U)
Processor ARK ID64615
Intel Identity Protection Technology version0.00
Weight and Dimensions IconWeight and Dimensions
Width- mm

Related product manuals