Troubleshooting Cooling Fans
CAUTION: Many repairs may only be done by a certified service technician. You should only perform
troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or
telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your
warranty. Read and follow the safety instructions that came with the product.
1. Open the system.
2. Reseat the fan or the fan's power cable.
3. If the fan functions properly, close the system.
If the problem persists, see Getting Help.
Troubleshooting System Memory
CAUTION: Many repairs may only be done by a certified service technician. You should only perform
troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or
telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your
warranty. Read and follow the safety instructions that came with the product.
1. If the system is operational, run the appropriate diagnostic test. See Using System Diagnostics for available
diagnostic tests.
If diagnostics indicates a fault, follow the corrective actions provided by the diagnostic program.
2. If the system is not operational, turn off the system and attached peripherals, and unplug the system from the
power source. Wait at least 10 seconds and then reconnect the system to power.
3. Turn on the system and attached peripherals and note the messages on the screen.
If an error message is displayed indicating a fault with a specific memory module, go to step 12.
4. Enter the System Setup and check the system memory setting. Make any changes to the memory settings, if
needed.
If the memory settings match the installed memory but a problem is still indicated, go to step 12.
5. Turn off the system and attached peripherals, and disconnect the system from the electrical outlet.
6. Open the system.
7. Check the memory channels and ensure that they are populated correctly.
8. Reseat the memory modules in their sockets.
9. Close the system.
10. Enter the System Setup and check the system memory setting.
If the problem is not resolved, proceed with the next step.
11. Open the system.
12. If a diagnostic test or error message indicates a specific memory module as faulty, swap or replace the module
with a known good memory module.
13. To troubleshoot an unspecified faulty memory module, replace the memory module in the first DIMM socket with a
module of the same type and capacity.
If an error message is displayed on the screen, this may indicate a problem with the installed DIMM type(s),
incorrect DIMM installation, or defective DIMM(s). Follow the on-screen instructions to resolve the problem. For
more information, see General Memory Module Installation Guidelines.
14. Close the system.
129

Table of Contents

Other manuals for Dell PowerEdge R720xd

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Dell PowerEdge R720xd and is the answer not in the manual?

Dell PowerEdge R720xd Specifications

General IconGeneral
Tcase70 °C
Bus typeQPI
SteppingM1
FSB ParityNo
Scalability2S
Processor cache10 MB
Processor cores4
Processor modelE5-2609
System bus rate6.4 GT/s
Processor seriesIntel Xeon E5-2600
Processor socketLGA 2011 (Socket R)
Processor codenameSandy Bridge EP
Motherboard chipsetIntel C600
Number of QPI links2
Processor frequency2.4 GHz
Processor cache typeSmart Cache
Processor manufacturerIntel
Processor package size52.5 x 45.0 mm
Processor front side bus- MHz
Processor boost frequency2.50 GHz
Processor operating modes64-bit
ECC supported by processorYes
Graphics & IMC lithography32 nm
PCI Express configurationsx4, x8, x16
Supported instruction setsAVX
Thermal Design Power (TDP)80 W
Number of processors installed1
CPU multiplier (bus/core ratio)24
Physical Address Extension (PAE)46 bit
Maximum number of PCI Express lanes40
Memory types supported by processorDDR3-SDRAM
Memory channels supported by processorQuad
Memory clock speeds supported by processor800, 1066 MHz
Memory bandwidth supported by processor (max)34.1 GB/s
Maximum internal memory supported by processor750 GB
HDD size3.5 \
Optical drive typeDVD-RW
Total storage capacity- GB
Maximum storage capacity32 TB
Number of HDDs installed-
Number of HDDs supported14
Memory slots24x DIMM
Internal memory8 GB
Memory clock speed1333 MHz
Maximum internal memory768 GB
Cabling technology10/100/1000Base-T(X)
USB 2.0 ports quantity3
PCI Express slots version3.0
Power supply1100 W
Compatible operating systemsMicrosoft Windows Server 2012 \\r Microsoft Windows Server 2012 Essentials\\r Microsoft Windows Server 2008 R2 \\r Novell SUSE Linux Enterprise Server\\r Red Hat Enterprise Linux
Sustainability certificatesENERGY STAR
Chassis typeRack (2U)
Processor ARK ID64588
Intel Secure Key Technology version1.00
Intel Identity Protection Technology version0.00
Weight and Dimensions IconWeight and Dimensions
Width- mm

Related product manuals