EasyManuals Logo
Home>Delta>Servo Drives>ASD-A2-3043 Series

Delta ASD-A2-3043 Series User Manual

Delta ASD-A2-3043 Series
721 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #201 background imageLoading...
Page #201 background image
Chapter 6 Control Mode of Operation ASDA-A2
6-46 Revision February, 2017
6.4.2 Control Structure of Torque Mode
The basic control structure is as the following diagram:
The torque command unit is to select torque command source according to Section 6.4.1, including
the scaling (P1-41) setting and S-curve setting. The current control unit manages the gain
parameters of the servo drive and calculates the current for servo motor in time. Since the current
control unit is very complicated, and is not relevant to the application. There is no need to adjust
parameters. Only command end setting is provided.
The structure of torque command unit is as the following diagram.
The upper path is the command from register while the lower one is external analog command.
The command is selected according to the status of TCM0, TCM1 and P1-01 (T or Tz). The torque
represented by analog voltage command can be adjusted via the scaling and can obtain a
smoother response via low-pass filter.

Table of Contents

Other manuals for Delta ASD-A2-3043 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Delta ASD-A2-3043 Series and is the answer not in the manual?

Delta ASD-A2-3043 Series Specifications

General IconGeneral
BrandDelta
ModelASD-A2-3043 Series
CategoryServo Drives
LanguageEnglish

Related product manuals