2
Analog voltage output: 0 to 10 V (resistive load > 1,000 Ω); for OUT1 and OUT2 only
Output functions
Control output, alarm output or proportional output (proportional output is only applicable in the model with linear
voltage and current output for OUT1, OUT2)
Alarm modes 13 alarm modes available
Communication RS-485 digital communication; supports baud rate 2,400 to 115,200 bps
Communication
protocol
Supports Modbus ASCII/RTU
Extension port The extension port transmits 24 V power supply and communication signals to extension module DTC2000.
Vibration resistance 10 to 55 Hz 10m/s
2
3 axes 10mins
Shock resistance Max. 300m/s
2
3 axes 6 directions, 3 times each
Ambient temperature 0 to +50°C
Storage temperature -20 to +65°C
Operation altitude < 2,000m
Ambient humidity 35 to 85% RH (non-condensing)
Pollution degree 2
Product Profile & Outline
DTE10P
1 I/O terminals
2 Status LED
3 Display and setup unit
4 DIN rail clip
5 Power input port
6 RS-485 communication port
7 Extension module fixing clip
8 Extension port
Panel Layout
Operation