EasyManuals Logo
Home>Delta>DC Drives>VFD110ED43S

Delta VFD110ED43S User Manual

Delta VFD110ED43S
447 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #406 background imageLoading...
Page #406 background image
Chapter 16 Safe Torque Off Function | VFD-ED
16-11
16-6 Fault Codes Related to STO
06-16
Present Fault Record
06-17
Second Most Recent Fault Record
06-18
Third Most Recent Fault Record
06-19
Fourth Recent Fault Record
06-20
Fifth Most Recent Fault Record
06-21
Sixth Most Recent Fault Record
Control Mode
VF VFPG SVC FOCPG FOCPM Default: 0
Settings 72: Safe torque loss (STL1)
76: Safe torque output stops (STO)
77: Safe torque loss 2 (STL2)
78: Safe torque loss 3 (STL3)
Fault Code Reading Description
72 (STL1) Safe torque loss (STL1) STO1SCM1 internal circuit error.
76 (STO) Safe torque output stops (STO)
Safe Torque Off function is enabled while Pr.06-
49 is set to 0000h or 0002h.
77 (STL2) Safe torque loss 2 (STL2) STO2SCM2 internal circuit error.
78 (STL3) Safe torque loss 3 (STL3)
STO1SCM1 and STO2SCM2 internal circuit
error.