Chapter 11 Summary of Parameter SettingsMS300
232
Pr.
Explanation
Settings
Default
05-68
No-Load Current for
Induction Motor 3 (A)
0.00–Pr.05-64 default
Depending
on the
model
power
05-69
Stator Resistance (Rs) for
Induction Motor 3
0.000–65.535
Depending
on the
model
power
05-70
Full-Load Current for
Induction Motor 4 (A)
10–120% of the drive’s rated current
Depending
on the
model
power
05-71
Rated Power for Induction
Motor 4 (kW)
0.00–655.35 kW
Depending
on the
model
power
05-72
Rated Speed for Induction
Motor 4 (rpm)
0–xxxxx rpm (Depending on the motor’s number of poles)
1710 (60 Hz, 4 poles); 1410 (50 Hz, 4 poles)
Depending
on the
motor’s
number of
poles
05-73
Number of Poles for
Induction Motor 4
2–20
4
05-74
No-Load Current for
Induction Motor 4 (A)
0.00–Pr.05-70 default
Depending
on the
model
power
05-75
Stator Resistance (Rs) for
Induction Motor 4
0.000–65.535
Depending
on the
model
power

Table of Contents

Other manuals for Delta VFD4A8MS23ANSAA

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Delta VFD4A8MS23ANSAA and is the answer not in the manual?

Delta VFD4A8MS23ANSAA Specifications

General IconGeneral
BrandDelta
ModelVFD4A8MS23ANSAA
CategoryDC Drives
LanguageEnglish

Related product manuals