Follow local codes and requirements for installing and using
disconnect switches.
Danger!
Keep switch or circuit-breaker in building installation, close to
the equipment, within easy reach of the operator and clearly
marked.
2.7.3. Disconnecting Corded Units
LAC-8 cord-connected ovens include models LAC1-38-8 and LAC1-67-8. To disconnect a
corded unit, unplug the cord from the power source.
2.7.4. Disconnecting Units with Optional Disconnect Switch
The LAC-8 Series oven has an optional Disconnect Switch. This
Disconnect Switch is located on the front of the oven, typically near the
controls, and connected to the load break switch behind the panel that
disconnects or connects power from the main line. When a risk of
personal injury or damage to the LAC-8 Series oven exists, turn off the
Disconnect Switch. This shuts off all electrical power to the oven.
2.8. Airflow Switches: Recirculation and Forced Exhaust
The airflow switch is used to prove airflow at the recirculation and exhaust fans when the
heater is being energized in the LFC Oven. The model LFC1-38-8 has two airflow
switches (one recirculation switch and one exhaust switch) while the model LFC2-12-8
has three airflow switches (two recirculation switches and one exhaust switch).
Locate the recirculation fan airflow switches in the control compartment (Figure 2).
Locate the forced exhaust fan on the back of the oven (Figure 3).
For test and operation of the airflow switches, refer to Section 6.5.1.
Figure 1. Disconnect
Switch.