DR4088LN-CS / GND / OPTO 2021-04-21
P 8
www.digikeijs.com
® R-Bus, B-Bus are trademarks which are registered in the name of Modelleisenbahn GmbH. XpressNet and RS-Bus is a trademark registered in the name of Lenz
3.2 Programming DR4088LN-xx with further DR4088 at the S88(N) connecon
3.2.1 Programming with the DR5000
1. connect the DR5000 to the DR4088LN-xx to be programmed
(normally it is not necessary to disconnect other feedback modules from the LocoNet®)
2. open the DR5000 tool.
3. First, the DR4088LN-xx must be assigned the start address.
Open the turnout control panel that contains the desired start address that the DR4088LN-xx is to receive.
4. Press the programming button on the DR4088LN-xx. The green LED starts flashing to indicate that the DR4088LN-xx is in programming mode.
5. to assign the start address switch the turnout address e.g. 1 once (so only red or green!).
6. The green LED on the DR4088LN-xx now flashes in a different clock pulse to indicate that the DR4088LN-xx is expecting the number of feedbacks next.
The number of feedback signals is again sent to the DR4088LN-xx via a switch command.
Example:
DR4088LN-xx DR4088
Start address 1 Number of feedback units 32 The switch address 32 must be sent here.
DR4088LN-xx 2x DR4088S
tart address 1 Number of feedback units 48 The switch address 48 must be sent here.
R4088LN-xx 3x DR4088
Start address 1 Number of feedback sensors 64 The switch address 64 must be sent here
.etc.
7. In the DR5000 tool, call the turnout control panel containing the address corresponding to the number of feedback signals. Again, only red or green
switching applies.The DR4088LN-xx automatically terminates the programming mode and is now programmed with the start address and the number
of feedbacks.
Aenon! At the S88 connecon of the DR4088LN-xx A maximum of 15 DR4088 can be connected to the S88 connecon of the DR4088LN-xx. This results
in a maximum number of 256 feedback contacts that a DDR4088LN-xx can manage.
Example: DR4088LN-xx 15x DR4088 Start address 1 Occupied feedback device Address range 1 - 256