CD0050, CRD1050 Disposal
21
11 Disposal
!
➤ Place the packaging material in the appropriate recycling waste bins wherever
possible.
M
If you wish to finally dispose of the product, ask your local recycling centre
or specialist dealer for details about how to do this in accordance with the
applicable disposal regulations.
12 Troubleshooting
The meaning of the red LED (fig. 2 3, page 2)
For operational faults it illuminates several times. The number of pulses depends on
the type of fault.
Each flash lasts for one quarter of a second. After the series of impulses a pause
follows. The sequence for the fault is repeated every four seconds.
WARNING! Children beware!
Before disposing of your old refrigerator:
•
Dismantle the drawers.
•
Leave the shelves in the refrigerator so that children cannot climb
inside.
Number of
flashes
Fault Possible cause
1 Supply voltage The supply voltage is outside of the set
range.
2 Excessive fan current The fan loads the electronics unit with more
than 1 A.
3 The motor doesn't start The rotor is jammed.
The pressure difference in the cooling system
is too high (> 5 bar).
4 Speed too low If the cooling system is overloaded, the
minimum speed of the motor of 1850 RPM
cannot be maintained.
5 Overheating of the electronics
unit
If the cooling system is loaded too heavily or
the temperature is set too high, the electron-
ics can overheat.
CD0050-CRD1050-O-EN-FR.book Seite 21 Dienstag, 10. Oktober 2017 11:13 11