CVH1525(G), CVC1700G Installing the device
21
7 Installing the device
7.1 Selecting the installation location
When selecting the installation location, observe the following instructions:
• There must be air vents with a cross-section of at least 150 cm
2
in the installation
location.
• Make sure that the minimum distances (fig. 4, page 5 and fig. 5, page 6) are
observed.
• Ensure that there are no drafts at the installation location.
7.2 Installation steps
1. Create a cut-out in the countertop (fig. 6, page 6).
2. Attach a rubber seal between the countertop and the device.
I
3. Fasten the device in the countertop (fig. 7, page 7).
7.3 Connecting the device to the gas supply
!
NOTE
Contact the manufacturer if the device is not supplied with a rubber seal.
The assembly and installation of the gas connection must be performed
by a qualified person who has demonstrated skill and knowledge related
to the construction, installation and operation of gas appliances and has
received safety training to identify and avoid the hazards involved.
WARNING! Explosion hazard
• Only use LP gas containers with a certified pressure regulator.
• Compare the pressure information on the data plate with the pres-
sure information on the LP gas containers.
• Avoid any stress on the gas pipe system during and after installation.